Eaton xPole PL Miniature Circuit Breaker, 2-Pole, 10 A, Type C, 48 V DC, 10 kA Breaking Capacity

小計(1 件)*

TWD2,227.00

(不含稅)

TWD2,338.35

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 17 件從 2026年1月26日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD2,227.00

* 參考價格

RS庫存編號:
864-4358
Distrelec 貨號:
302-55-631
製造零件編號:
242401 PLSM-C10/2-MW
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Product Type

Miniature Circuit Breaker

Number of Poles

2

Current Rating

10 A

Tripping Characteristics

Type C

Rated DC Voltage

48 V

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

xPole

Series

PL

Terminal Type

Secure Terminal Connection

Depth

75mm

Width

80 mm

Standards/Approvals

IEC/EN 60898-1

不適用

COO (Country of Origin):
RO

Eaton MCB, 10A Current Rating, Type C Tripping Characteristics - 242401 PLSM-C10/2-MW


This MCB is a high-performance circuit breaker designed for efficient residential circuit protection. With a compact size of 35mm in width and 80mm in length, it allows for seamless installation on a standard DIN rail. Equipped with a current rating of 10A, this device is suitable for various electrical applications, ensuring safety and reliability.

Features & Benefits


• Type C MCB tripping characteristics for reliable fault protection

• Breaks fault currents up to 10 kA effectively

• Rated for 400V AC and 48V DC applications

• Easy to reset with a toggle switch actuator

• Designed for swift DIN rail mounting to enhance installation efficiency

• Compact design for space-efficient housing in electrical control systems

Applications


• Ideal for domestic electrical installations

• Utilised in commercial electrical systems for protection

• Suitable for automation systems requiring reliable circuit protection

• Often employed in distribution boards for efficient power management

What is the significance of the tripping characteristics in this device?


The Type C tripping characteristic enables quick response to high current surges, making it suitable for applications with inductive loads such as motors or transformers, while ensuring minimal nuisance tripping.

How does the breaking capacity impact performance?


With a breaking capacity of 10 kA, the circuit breaker effectively interrupts fault currents, protecting downstream circuits and reducing the risk of damage to electrical equipment.

Can it be used in both AC and DC applications?


Yes, the device is rated for both 400V AC and 48V DC, providing versatility for various installations across residential and commercial environments.

Note

Eaton formerly known as Moeller

相關連結