Eaton xEffect MCB, 3P, 16A Curve D, 240 → 415V AC, 60V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 847-3535
- 製造零件編號:
- 102270 FAZ-D16/3-NA
- 製造商:
- Eaton
小計(1 件)*
TWD5,113.00
(不含稅)
TWD5,368.65
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 2 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD5,113.00 |
* 參考價格
- RS庫存編號:
- 847-3535
- 製造零件編號:
- 102270 FAZ-D16/3-NA
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Number of Poles | 3 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 240 → 415V | |
| Rated DC Voltage | 60V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Width | 105mm | |
| Length | 53.1mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 76mm | |
| Terminal Contact Type | Screw | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Number of Poles 3 | ||
Current Rating 16A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 240 → 415V | ||
Rated DC Voltage 60V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Width 105mm | ||
Length 53.1mm | ||
Mounting Style DIN Rail Mount | ||
Depth 76mm | ||
Terminal Contact Type Screw | ||
Eaton MCB, 16A Current Rating, Type D Tripping - FAZ Series - 102270 FAZ-D16/3-NA
Need robust protection against equipment failure caused by electrical surges? Opt for this MCB from Eaton. As it has D-type tripping characteristics, it trips at 10 to 20 times its current rating of 16A, making it suitable for use in heavy-duty applications like control instrumentation and fluorescent lighting. An IP40 rating indicates the unit is protected against wires and tools larger than 1mm in size, reducing the risk of electric shocks during installation and maintenance.
Features & Benefits
• Designed for DIN rail mounting for ease of installation
• Broad operating temperature range of -25°C to +75°C for use in demanding environments
• Broad operating temperature range of -25°C to +75°C for use in demanding environments
How do I choose the right MCB?
There are several factors to consider when choosing your MCB. You should select a unit that has a breaking capacity and tripping characteristics that match the likely strength of any surges that may occur in your system. The MCB should also have an appropriate pole configuration for the number of circuits it will need to break in the event of an overload.
Note
Eaton formerly known as Moeller
相關連結
- Eaton xEffect MCB 16A Curve D 60V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve D 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 25 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve B 60V DC, 15 kA Breaking Capacity