Eaton xEffect MCB, 2P, 10A Curve D, 240 → 415V AC, 10 kA Breaking Capacity

小計(1 件)*

TWD3,432.00

(不含稅)

TWD3,603.60

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 6 件準備從其他地點送貨
  • 加上 4 件從 2026年1月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD3,432.00

* 參考價格

RS庫存編號:
847-3487
製造零件編號:
102187 FAZ-D10/2-NA
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Number of Poles

2

Current Rating

10A

Tripping Characteristics

Type D

Rated AC Voltage

240 → 415V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

xEffect

Circuit Breaker Type

MCB

Length

35.4mm

Width

105mm

Mounting Style

DIN Rail Mount

Depth

76mm

Eaton MCB, 10A Current Rating, 2 Poles - 102187 FAZ-D10/2-NA


This Eaton MCB is a reliable miniature circuit breaker designed for efficient circuit protection. Featuring a compact DIN rail mount design, it measures 35.4mm in width and 105mm in length, making it suitable for various installations. With a current rating of 10A and supporting voltage levels from 277 to 480V, this device is essential for safeguarding residential and commercial electrical systems.

Features & Benefits


• Type D circuit breaker protects against high inrush currents
• High breaking capacity allows interruption of currents up to 15kA
• Compact design fits standard 35mm DIN rail for easy installation
• Toggle switch reset actuator simplifies operation after tripping
• Current limiting design reduces peak let-through energy
• Reliable thermal-magnetic overcurrent protection enhances safety

Applications


• Ideal for residential circuit protection against overloads
• Suitable for branch circuit connections in commercial settings
• Utilised in motor control circuits for better performance
• Effective in protecting heating, ventilation, and air conditioning systems
• Used for machinery that requires reliable circuit interruptions

What is the significance of the Type D tripping characteristic?


The Type D tripping characteristic indicates that the circuit breaker can handle high inrush currents, making it suitable for inductive loads such as motors and transformers without nuisance tripping.

How does the high breaking capacity benefit my electrical system?


The high breaking capacity allows for the quick interruption of fault currents, reducing the risk of damage to the circuit and ensuring the safety of connected equipment.

Can this circuit breaker be reverse-fed?


Yes, it is designed to be suitable for reverse feed connections, thereby providing flexibility in installation configurations.

What type of load can this miniature circuit breaker support?


It is designed to support both lighting circuits and motor control systems, ensuring efficient operation across various applications.

Note