Eaton xEffect MCB, 3P, 50A Curve C, 240 → 415V AC, 10 kA Breaking Capacity
- RS庫存編號:
- 847-3406
- 製造零件編號:
- 278878 FAZ-C50/3
- 製造商:
- Eaton
小計(1 件)*
TWD4,195.00
(不含稅)
TWD4,404.75
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 3 件準備從其他地點送貨
- 加上 2 件從 2026年1月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,195.00 |
* 參考價格
- RS庫存編號:
- 847-3406
- 製造零件編號:
- 278878 FAZ-C50/3
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Number of Poles | 3 | |
| Current Rating | 50A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240 → 415V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 54mm | |
| Width | 85mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 73mm | |
| Model Number | 278878 | |
| Application | Commercial, Residential | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Number of Poles 3 | ||
Current Rating 50A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240 → 415V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 54mm | ||
Width 85mm | ||
Mounting Style DIN Rail Mount | ||
Depth 73mm | ||
Model Number 278878 | ||
Application Commercial, Residential | ||
Eaton FAZ Series Circuit Breakers
The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eatons FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.
Features and Benefits
The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Eaton 3-Pole MCB, 50A Current Rating, C Curve - FAZ Series - 278878 FAZ-C50/3
Features & Benefits
• Lifespan of up to 10,000 operations for consistent reliability
• Wide operating temperature range between -40°C and +75°C, so withstands the demands of extreme conditions
• Captive screw terminals to reduce the chance of you losing screws when they're undone
• Suitable for international use as it meets IEC 60947-2 safety standards for low-voltage circuit breakers
• Wide operating temperature range between -40°C and +75°C, so withstands the demands of extreme conditions
• Captive screw terminals to reduce the chance of you losing screws when they're undone
• Suitable for international use as it meets IEC 60947-2 safety standards for low-voltage circuit breakers
What material is this MCB's housing made from?
This MCB has nylon housing to protect it against dirt and moisture. The robust enclosure also protects against abrasion and bumps to extend the breaker's life in harsh operating environments.
Note
Eaton formerly known as Moeller
相關連結
- Eaton xEffect MCB 50A Curve C 10 kA Breaking Capacity
- Eaton xEffect MCB 50A Curve C 96V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 50A Curve C 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 50A Curve C 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 50A Curve C 60V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 50A Curve C 60V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 50A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 50A Curve C 60V DC, 10 kA Breaking Capacity