Eaton xEffect MCB, 3P, 25A Curve C, 240 → 415V AC, 10 kA Breaking Capacity
- RS庫存編號:
- 847-3320
- Distrelec 貨號:
- 304-23-025
- 製造零件編號:
- 278875 FAZ-C25/3
- 製造商:
- Eaton
小計(1 件)*
TWD3,546.00
(不含稅)
TWD3,723.30
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 5 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD3,546.00 |
* 參考價格
- RS庫存編號:
- 847-3320
- Distrelec 貨號:
- 304-23-025
- 製造零件編號:
- 278875 FAZ-C25/3
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Number of Poles | 3 | |
| Current Rating | 25A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240 → 415V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 54mm | |
| Width | 85mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 73mm | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Number of Poles 3 | ||
Current Rating 25A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240 → 415V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 54mm | ||
Width 85mm | ||
Mounting Style DIN Rail Mount | ||
Depth 73mm | ||
Eaton MCB, 25A Current Rating, 3 Poles - 278875 FAZ-C25/3
This is a high-performance MCB designed for effective electrical circuit protection. With dimensions of 54mm in width by 80mm in length, this 3-pole miniature circuit breaker ensures reliable performance in various applications. It boasts a current rating of 25A and is built to achieve compliance with industry standards.
Features & Benefits
• Type C Circuit Breaker provides reliable operation for inductive loads
• Breaking Capacity of 10 kA safeguards against short circuits
• Easy installation on DIN Rail simplifies panel assembly
• Thermal-magnetic design ensures dual protection against overloads
• Compact dimensions allow for efficient use of panel space
• Toggle switch reset actuator enables straightforward operation
• Breaking Capacity of 10 kA safeguards against short circuits
• Easy installation on DIN Rail simplifies panel assembly
• Thermal-magnetic design ensures dual protection against overloads
• Compact dimensions allow for efficient use of panel space
• Toggle switch reset actuator enables straightforward operation
Applications
• Used for branch circuit protection in electrical systems
• Ideal for protecting motors and high inrush equipment
• Suitable for internal and external socket circuits
• Perfect for controlling loads leaving the equipment
• Applicable in HVACR installations and motor controllers
• Ideal for protecting motors and high inrush equipment
• Suitable for internal and external socket circuits
• Perfect for controlling loads leaving the equipment
• Applicable in HVACR installations and motor controllers
How does the circuit breaker's Type C characteristic enhance its suitability for inductive loads?
The Type C characteristic is specifically designed for medium inrush currents typical of inductive loads like motors. It provides a magnetic trip point that prevents nuisance tripping, ensuring the device remains operational during brief surges.
What protective measures are in place to handle potential short circuits?
With a breaking capacity of 10 kA at maximum voltage rating, the device is engineered to interrupt high fault currents quickly, minimising potential damage to the electrical system and ensuring continued safety in operations.
In what environments can this MCB be effectively used?
It is well-suited for diverse environments, including industrial, commercial, and residential spaces where dependable electrical circuit protection is vital. Its flexibility allows integration within control panels, contributing to comprehensive circuit protection.
Note
Eaton formerly known as Moeller
相關連結
- Eaton xEffect MCB 25A Curve C 10 kA Breaking Capacity
- Eaton xEffect MCB 25A Curve C 96V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 25A Curve C 60V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 25A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 25A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 25A Curve D 10 kA Breaking Capacity
- Eaton xEffect MCB 25A Curve D 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB Mini Circuit Breaker3P 240 → 415V AC, 10 kA Breaking Capacity