Lovato Modulo P2MB Miniature Circuit Breaker, 3-Pole, 100 A, Type C, 400 V AC, 60 V DC, 10 kA Breaking Capacity

小計(1 件)*

TWD4,654.00

(不含稅)

TWD4,886.70

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD4,654.00

* 參考價格

RS庫存編號:
825-6163
製造零件編號:
P2MB3PC100
製造商:
Lovato
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Lovato

Number of Poles

3

Product Type

Miniature Circuit Breaker

Current Rating

100 A

Tripping Characteristics

Type C

Rated AC Voltage

400 V

Rated DC Voltage

60 V

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

Modulo

Series

P2MB

Terminal Type

Screw

IP Rating

IP20

Height

85mm

Width

81 mm

Standards/Approvals

CSA, cURus, EAC, IEC/EN/BS 60898-1, IEC/EN/BS 60947-2, UL 1077

Depth

80mm

Tripping Mechanism

Thermal Magnetic

Break Time

Instantaneous

不適用

COO (Country of Origin):
IT

Lovato P2MB Series MCB, 100A Current Rating, 10 kA Breaking Capacity (at Maximum Voltage Rating) - P2MB3PC100


The Lovato ModuLo MCB is an important electrical safety device designed to protect circuits in various settings. It effectively responds to overloads and short circuits, ensuring the safety of electrical installations. With a current rating of 100 A and Type C tripping characteristics, it is well-suited for applications with fluctuating load conditions.

Features & Benefits


• Strong breaking capacity of 10 kA for enhanced safety

• 3 pole design suitable for three-phase circuit Applications

• Operates efficiently at rated AC voltages of 230 V and 400 V

• Easy installation with a standard DIN rail mounting system

• Consistent tripping performance with Type C characteristics

• Compatible with other components from the ModuLo range

Applications


• Protection for machinery in industrial automation systems

• Reliable electrical distribution in commercial buildings

• Circuit interruption in mechanical systems

• Prevention of overload damage in motor circuits

What types of electrical installations can it be used with?


It is suitable for various industrial and commercial electrical installations, particularly those featuring three-phase systems.

How can I ensure proper installation?


Use an appropriate DIN rail for mounting and adhere to local electrical safety regulations.

What is the procedure for resetting the device after it has tripped?


After addressing the issue that caused the trip, return the switch to the ON position.

Is it compatible with other circuit protection devices?


Yes, it is designed to work effectively with other devices from the same range, ensuring proper coordination.

What maintenance is required over time?


Regular visual inspections are advisable to ensure continued proper functioning, especially in dusty or humid environments.