Schneider Electric Acti9 iC60H Miniature Circuit Breaker, 2-Pole, 40 A, Type C, 12 V, 133 V, 220 V, 240 V, 380 V, 415 V,

小計(1 件)*

TWD3,225.00

(不含稅)

TWD3,386.25

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 15 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD3,225.00

* 參考價格

RS庫存編號:
791-3354
製造零件編號:
A9F54240
製造商:
Schneider Electric
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Schneider Electric

Product Type

Miniature Circuit Breaker

Number of Poles

2

Tripping Characteristics

Type C

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

Acti9

Series

iC60H

Terminal Type

Screw

IP Rating

IP20

Height

85mm

Depth

78.5mm

Standards/Approvals

RoHS, REACH

Reset Actuator Type

Rocker

Break Time

Instantaneous

Tripping Mechanism

Thermal Magnetic

COO (Country of Origin):
BG

Schneider Electric Acti9 iC60H Series Miniature Circuit Breaker, 40A Current, Type C Tripping Characteristics - A9F54240


This miniature circuit breaker provides overcurrent protection for AC and DC supply systems in industrial and commercial electrical installations, using a thermal-magnetic trip mechanism and a rocker reset actuator for straightforward manual operation. It is configured as a two-pole device suitable for clip-on rail mounting and designed to deliver interruption performance across a broad range of voltages and frequencies.

Features & Benefits


• 40A thermal-magnetic trip offering dependable overcurrent protection
• Type C instantaneous characteristic protecting mixed load types
• 10 kA breaking capacity at designated conditions for fault clearance
• Screw terminals accepting up to 35 mm2 rigid conductors for robust connections
• IP20 enclosure rating permitting indoor panel installation
• Clip-on mounting with 36mm module width for Compact distribution layouts

Applications


• Suitable for protecting motor circuits with moderate inrush currents
• Ideal for distribution boards in automation control cabinets
• Used for AC and DC control circuits requiring selective protection
• Can be used for branch protection in commercial electrical panels

What Terminal sizes and conductor types are supported?


Single terminals accept 1 to 35 mm2 rigid or 1 to 25 mm2 flexible conductors with 14mm wire stripping length.

How does the device indicate a trip condition?


A contact position indicator and trip indicator provide clear local signalling of tripped status.

What environmental ranges can it withstand during operation?


It is rated for operation between -35 to 70 °C and relative humidity up to 95% at 55 °C.

What mechanical and electrical endurance can be expected?


Mechanical durability is 20,000 cycles and electrical endurance is 10,000 cycles.

相關連結