Schneider Electric Acti9 Acti9 iDT40T Miniature Circuit Breaker, 3-Pole, 16 A, Type C, 400 V ac AC, 4500 A Breaking

小計(1 件)*

TWD3,728.00

(不含稅)

TWD3,914.40

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 8 件從 2026年1月27日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD3,728.00

* 參考價格

RS庫存編號:
239-9969
製造零件編號:
A9P22316
製造商:
Schneider Electric
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Schneider Electric

Number of Poles

3

Product Type

Miniature Circuit Breaker

Current Rating

16 A

Tripping Characteristics

Type C

Rated AC Voltage

400 V ac

Breaking Capacity

4500A

Mount Type

Clip-on

Range

Acti9

Series

Acti9 iDT40T

Terminal Type

Tunnel

Height

85mm

Depth

74mm

Standards/Approvals

EN/IEC 60898-1, EN/IEC 60947-2

Width

54 mm

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

COO (Country of Origin):
HU

Schneider Electric Acti9 iDT40T Series MCB, 3 Poles, 16A Current Rating - A9P22316


This MCB is a compact 3 Phase circuit breaker designed for electrical distribution applications. Compliant with EN/IEC standards, it offers robust protection for circuits, with a rated current of 16A and operational voltage of 400V. Its DIN rail mount design ensures easy installation, making it a practical choice for various settings.

Features & Benefits


• Thermal-magnetic trip technology improves circuit protection reliability

• Type C Circuit Breaker suitable for commercial and industrial loads

• 4500A breaking capacity ensures quick fault clearance

• Designed for ease of use with toggle control and trip indicator

Applications


• Used with three phase electrical systems for distribution

• Ideal for circuit protection in commercial facilities

• Suitable for integration in panels requiring MCBs

• Used for safeguarding motors and inductive loads

What is the significance of the breaking capacity for this device?


The breaking capacity of 4500A ensures that the device can safely interrupt excessive fault currents, protecting other connected devices and preventing potential damage in the electrical system.

How does the thermal-magnetic technology enhance protection?


This technology combines thermal protection for overloads and magnetic tripping for short circuits, ensuring comprehensive performance against different fault conditions while maintaining system integrity.

Can this circuit breaker be padlocked for added safety?


Yes, the design includes a padlocking option, providing an additional layer of safety by preventing accidental operation during maintenance or when the circuit is not in use.

What is the ambient temperature range for operation?


It operates effectively within a temperature range of -25 to 70 °C, making it suitable for varied environmental conditions.