Schneider Electric Acti9 A9F7 Miniature Circuit Breaker, 2-Pole, 63 A, Type B, 500 V ac AC, 125 V DC, 36 kA Breaking
- RS庫存編號:
- 428-819
- 製造零件編號:
- A9F76263
- 製造商:
- Schneider Electric
小計(1 件)*
TWD14,241.00
(不含稅)
TWD14,953.05
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年2月09日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD14,241.00 |
* 參考價格
- RS庫存編號:
- 428-819
- 製造零件編號:
- A9F76263
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 2 | |
| Current Rating | 63 A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 500 V ac | |
| Rated DC Voltage | 125 V | |
| Breaking Capacity | 36kA | |
| Mount Type | DIN Rail | |
| Range | Acti9 | |
| Series | A9F7 | |
| Terminal Type | Single Terminal | |
| IP Rating | IP20 | |
| Standards/Approvals | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 | |
| Height | 85mm | |
| Depth | 78.5mm | |
| Width | 36 mm | |
| Tripping Mechanism | Thermal Magnetic | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 2 | ||
Current Rating 63 A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 500 V ac | ||
Rated DC Voltage 125 V | ||
Breaking Capacity 36kA | ||
Mount Type DIN Rail | ||
Range Acti9 | ||
Series A9F7 | ||
Terminal Type Single Terminal | ||
IP Rating IP20 | ||
Standards/Approvals EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 | ||
Height 85mm | ||
Depth 78.5mm | ||
Width 36 mm | ||
Tripping Mechanism Thermal Magnetic | ||
- COO (Country of Origin):
- FR
The Schneider Electric Acti9 iC60N MCB is a low voltage miniature circuit breaker. It is a 2P circuit breaker with 2 protected poles, 63A rated current and B tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2.
Combine short circuit and overload currents protection
Visitrip system for fast detection of faulty outgoers for shorter repair times
VisiSafe system for offering enhanced security when it comes to circuit protection
Option to add auxiliaries and remote monitoring and residual current device
相關連結
- Schneider Electric Acti9 Acti9 iC60 MCB 32A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 40A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 50A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 50A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 25A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 500mA Curve D 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 50A Curve B 10 kA Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 63A 500V AC, 1000 mA Breaking Capacity