Testo 510 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 100hPa
- RS庫存編號:
- 920-5188
- 製造零件編號:
- 0563 0510
- 製造商:
- Testo
小計(1 件)*
TWD6,660.00
(不含稅)
TWD6,993.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 22 件從 2026年1月26日 起發貨
- 加上 15 件從 2026年2月04日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD6,660.00 |
* 參考價格
- RS庫存編號:
- 920-5188
- 製造零件編號:
- 0563 0510
- 製造商:
- Testo
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Testo | |
| Best Accuracy | +1.5 (0.40 → 40 inH2O) %, +1.5 (1.01 → 100 hPa) % | |
| Number of Pressure Ports | 2 | |
| Maximum Pressure Measurement | 100hPa | |
| Minimum Pressure Measurement | 0hPa | |
| Pressure Port Type | Differential | |
| Model Number p | 510 | |
| IP Rating | IP40 | |
| Battery Type | AAA | |
| Display Type | Backlit LCD | |
| Weight | 90g | |
| Maximum Operating Temperature | +50°C | |
| Width | 25mm | |
| Dimensions | 46 x 25 x 119mm | |
| Length | 46mm | |
| Height | 119mm | |
| Minimum Operating Temperature | 0°C | |
| 選取全部 | ||
|---|---|---|
品牌 Testo | ||
Best Accuracy +1.5 (0.40 → 40 inH2O) %, +1.5 (1.01 → 100 hPa) % | ||
Number of Pressure Ports 2 | ||
Maximum Pressure Measurement 100hPa | ||
Minimum Pressure Measurement 0hPa | ||
Pressure Port Type Differential | ||
Model Number p 510 | ||
IP Rating IP40 | ||
Battery Type AAA | ||
Display Type Backlit LCD | ||
Weight 90g | ||
Maximum Operating Temperature +50°C | ||
Width 25mm | ||
Dimensions 46 x 25 x 119mm | ||
Length 46mm | ||
Height 119mm | ||
Minimum Operating Temperature 0°C | ||
豁免
- COO (Country of Origin):
- CN
testo 510 Differential Pressure Manometer Kit 510
Air-conditioning systems are equipped with filters which prevent dirt from the outside air entering the indoor air. These filters are inspected regularly for continuing full functionality. Pressure is measured in front of and behind the filter. The result is the differential pressure. If differential pressure is too high, the filter is contaminated and needs changing. The testo 510 digital manomenter is an all-in-one, low pressure measurement solution. It can measure total external static pressure, differential pressure, duct velocities and manifold pressures. It can measure air flow with a pitot tube (not supplied). The 510 measures differential pressures in a range of 0 - 100 hPa. The differential pressure measurement is temperature-compensated for exact readings. The readings can be displayed in pascal over the entire measuring range. Magnets on the rear of the instrument allow hands-free work.
Features and Benefits
Provides pressure, differential pressure and air velocity measurements
User-selectable units of measure (in H2O, mBar, hPa, PSI, mmH20, mmHg, Pa, inHg, fpm, m/s)
0-40 in H20 pressure measurement range
Auto or manual power-off
1-touch zeroing
Temperature and air density compensation for accurate air flow measurements
Fully-featured, temperature compensated sensor in a rugged, compact package
Backlit LCD display with 3-button operation
Magnetic back allows hands-free operation
Low battery indicator
Protective cap for safe storage
Protection to IP40
Dimensions 119 x 46 x 25 mm
Weight 90 g (with batteries and protective cap)
User-selectable units of measure (in H2O, mBar, hPa, PSI, mmH20, mmHg, Pa, inHg, fpm, m/s)
0-40 in H20 pressure measurement range
Auto or manual power-off
1-touch zeroing
Temperature and air density compensation for accurate air flow measurements
Fully-featured, temperature compensated sensor in a rugged, compact package
Backlit LCD display with 3-button operation
Magnetic back allows hands-free operation
Low battery indicator
Protective cap for safe storage
Protection to IP40
Dimensions 119 x 46 x 25 mm
Weight 90 g (with batteries and protective cap)
Contents
testo 510, belt pouch, hoses (x2), AAA batteries (x2), wrist strap, certificate of conformity
Testo Manometer, 100hPa Maximum, 2 Ports - 510 Series - 0563 0510
This Testo manometer measures the differential pressure in front of and behind an air filter, allowing you to tell if the filter is functioning as it should or if it's contaminated and needs changing. It helps to prevent clogged filters to ensure optimal performance. This versatile digital device can measure a range of values, including total external static pressure, differential pressure, duct velocities and manifold pressures.
Features & Benefits
• Backlit LCD (liquid-crystal display) screen for high visibility in dark work areas
• IP40 (ingress protection) rating for protection against wires and other objects greater than 1mm in size
• Wide operating temperature range of 0°C to +50°C for use in a variety of environments
• Measures pressures of up to 100hPa (hectopascals) for use in high-pressure systems
• IP40 (ingress protection) rating for protection against wires and other objects greater than 1mm in size
• Wide operating temperature range of 0°C to +50°C for use in a variety of environments
• Measures pressures of up to 100hPa (hectopascals) for use in high-pressure systems
Applications
• Air conditioning and heating systems
• Offices
• Laboratories
• Factories
• Offices
• Laboratories
• Factories
Can I use this device hands-free?
Yes, this device has magnets on the rear of the instrument, so you can attach it to a magnetic surface such as a metal panel or door. This allows you to use the device without having to hold it for greater ease of use.
testo Electronic Manifolds
The testo 550 series electronic manifolds with up to a 3-way valve bank are the ideal tools for regulating refrigerating systems. They are high quantity sensors for measuring pressure, vacuum and temperature.
Display condensation and vaporisation temperatures - the measured pressure on the suction and pressure side is shown on the display. The calculation and display of the respective condensation and evaporation temperatures for the selected refrigerant take place at the same time
Valve bank for temporary alteration to flow passages
35 refrigerants stored, selectable via memory
Display of cooling/heating output figures for comparison process - Carnot and Lorenz
Internal memory
Brass finish
Display of saturated steam valves
Protection to IP65
Valve bank for temporary alteration to flow passages
35 refrigerants stored, selectable via memory
Display of cooling/heating output figures for comparison process - Carnot and Lorenz
Internal memory
Brass finish
Display of saturated steam valves
Protection to IP65
相關連結
- Testo 512-2 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 2000mbar
- Testo 512-1 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 200mbar
- Testo 511 Absolute Manometer, Max Pressure Measurement 1200mbar
- Extech HD755 Differential Manometer, Max Pressure Measurement 13.85inH2O
- Extech HD750 Differential Manometer, Max Pressure Measurement 5psi
- Extech HD700 Differential Manometer, Max Pressure Measurement 2psi
- RS PRO Differential Manometer, Max Pressure Measurement 55.4inH2O
- RS PRO Differential Manometer, Max Pressure Measurement 150hPa