Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 1400 bar
- RS庫存編號:
- 261-4456
- 製造零件編號:
- DPI705EIS-1-10G-P1-H1-U0-OP0
- 製造商:
- Druck
小計(1 件)*
TWD38,339.00
(不含稅)
TWD40,255.95
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 10 件從 2026年11月16日 起發貨
- 加上 7 件從 2026年11月16日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD38,339.00 |
* 參考價格
- RS庫存編號:
- 261-4456
- 製造零件編號:
- DPI705EIS-1-10G-P1-H1-U0-OP0
- 製造商:
- Druck
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Druck | |
| Accuracy | +/-0.1%FS | |
| Product Type | Manometer | |
| Number of Pressure Ports | 1 | |
| Maximum Pressure Measurement | 1400bar | |
| Minimum Pressure Measurement | -25mbar | |
| Pressure Port Type | G1/8 | |
| Leak Testing | Yes | |
| Minimum/Maximum Recordings | Yes | |
| Model Number | DPI705EIS | |
| Intrinsically Safe | Yes | |
| Power Source | 4 x AA | |
| IP Rating | IP54 | |
| Maximum Overpressure | 1400bar | |
| Minimum Operating Temperature | -10°C | |
| Battery Type | AA | |
| Battery Life | 1year | |
| Display Type | LCD Backlight | |
| Maximum Operating Temperature | 50°C | |
| Length | 200mm | |
| Width | 95mm | |
| Standards/Approvals | CE, RCM, RoHS, UL 61010-1 | |
| Height | 43mm | |
| Weight | 563g | |
| Hazardous Area Certification | IECEx/ATEX | |
| 選取全部 | ||
|---|---|---|
品牌 Druck | ||
Accuracy +/-0.1%FS | ||
Product Type Manometer | ||
Number of Pressure Ports 1 | ||
Maximum Pressure Measurement 1400bar | ||
Minimum Pressure Measurement -25mbar | ||
Pressure Port Type G1/8 | ||
Leak Testing Yes | ||
Minimum/Maximum Recordings Yes | ||
Model Number DPI705EIS | ||
Intrinsically Safe Yes | ||
Power Source 4 x AA | ||
IP Rating IP54 | ||
Maximum Overpressure 1400bar | ||
Minimum Operating Temperature -10°C | ||
Battery Type AA | ||
Battery Life 1year | ||
Display Type LCD Backlight | ||
Maximum Operating Temperature 50°C | ||
Length 200mm | ||
Width 95mm | ||
Standards/Approvals CE, RCM, RoHS, UL 61010-1 | ||
Height 43mm | ||
Weight 563g | ||
Hazardous Area Certification IECEx/ATEX | ||
- COO (Country of Origin):
- GB
Druck Manometer, -25m bar Minimum Pressure Measurement, 1400 bar Maximum Pressure Measurement - DPI705EIS-1-10G-P1-H1-U0-OP0
This manometer is a portable pressure instrument designed for field and industrial use, providing measurements across a wide range from low negative pressures to very high pressures. It operates at ambient temperatures between -10°C and 50°C and is intended for tasks requiring both low-pressure sensitivity and high-pressure capability in environments where intrinsic safety and moderate ingress protection are necessary.
Features and Benefits:
• ±0.1%FS accuracy provides precise readings under varying conditions
• Intrinsically safe certification allows use in hazardous atmospheres
• LCD backlight display ensures visibility in low-light locations
• Leak testing capability enables verification of system integrity
• Battery powered by 4 AA cells extends on-site usability
• Intrinsically safe certification allows use in hazardous atmospheres
• LCD backlight display ensures visibility in low-light locations
• Leak testing capability enables verification of system integrity
• Battery powered by 4 AA cells extends on-site usability
Applications
• Suitable for pressure verification in hazardous plant areas
• Ideal for on-site leak detection and sealing checks
• Used with high-pressure systems up to 1400 bar
• Can be used for low-pressure calibration to -25 mbar
• Suitable for portable testing in general maintenance
• Ideal for on-site leak detection and sealing checks
• Used with high-pressure systems up to 1400 bar
• Can be used for low-pressure calibration to -25 mbar
• Suitable for portable testing in general maintenance
What power arrangement does the instrument use?
It runs from four AA batteries and typically sustains power for up to one year of intermittent use.
How is the device protected against dust and water ingress?
It carries an IP54 rating providing protection against limited dust ingress and splashing water.
Which connection does the pressure port employ?
The unit uses a G1/8 pressure port to Interface with test leads and fittings.
What standards and approvals support its electrical safety?
It conforms to CE, RCM and RoHS and meets UL 61010-1 electrical safety requirements.
What are the device's physical weight and form factor?
The instrument weighs 563 g and is a Compact handheld device with a slim profile.
相關連結
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 1400 bar
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 0.2 bar
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 2 bar
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 10 bar
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 70 bar
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 20 bar
- Druck DPI705EIS G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 0.35 bar
- Druck DPI705E G1/8 Manometer With 1 Pressure Port/s, Max Pressure Measurement 1400 bar