規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Manometer Kit | |
| Accuracy | ±1% +0.01 mbar | |
| Number of Pressure Ports | 2 | |
| Maximum Pressure Measurement | 10psi | |
| Minimum Pressure Measurement | 0mbar | |
| Pressure Port Type | Differential | |
| Minimum/Maximum Recordings | Yes | |
| Data Logging | Yes | |
| Model Number | 922/KIT | |
| IP Rating | IP40 | |
| Power Source | 4 AA Batteries | |
| Maximum Overpressure | 10psi | |
| Minimum Operating Temperature | 0°C | |
| Battery Type | AA | |
| Display Type | LCD | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 280, 60h | |
| Width | 77.5mm | |
| Height | 175mm | |
| Standards/Approvals | CE | |
| Length | 41.9mm | |
| Weight | 640g | |
| Hazardous Area Certification | NO | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Manometer Kit | ||
Accuracy ±1% +0.01 mbar | ||
Number of Pressure Ports 2 | ||
Maximum Pressure Measurement 10psi | ||
Minimum Pressure Measurement 0mbar | ||
Pressure Port Type Differential | ||
Minimum/Maximum Recordings Yes | ||
Data Logging Yes | ||
Model Number 922/KIT | ||
IP Rating IP40 | ||
Power Source 4 AA Batteries | ||
Maximum Overpressure 10psi | ||
Minimum Operating Temperature 0°C | ||
Battery Type AA | ||
Display Type LCD | ||
Maximum Operating Temperature 50°C | ||
Battery Life 280, 60h | ||
Width 77.5mm | ||
Height 175mm | ||
Standards/Approvals CE | ||
Length 41.9mm | ||
Weight 640g | ||
Hazardous Area Certification NO | ||
豁免
Fluke Manometer Kit, ±1 % rgd Accuracy, IP40 - FLUKE 922/KIT
This manometer kit is a handheld instrument for measuring differential and static pressure, Airflow and Air velocity in HVAC and industrial environments. It combines a micromanometer with colour‑coded hoses and a backlit LCD to aid clear readings on site, powered by AA batteries and supplied with a rugged holster and wrist strap for field use.
Features & Benefits
• Differential range to 10psi with ±1% rgd+0.01mbar accuracy provides precise pressure data
• Data logging stores up to 99 readings for later analysis
• Air velocity span to 16,000fpm enables broad duct measurements
• Temperature measurement from 0°C to 50°C supports environmental checks
• Resolution to 0.001inH2O captures fine pressure changes
• IP40 enclosure and robust housing withstand typical site conditions
• Data logging stores up to 99 readings for later analysis
• Air velocity span to 16,000fpm enables broad duct measurements
• Temperature measurement from 0°C to 50°C supports environmental checks
• Resolution to 0.001inH2O captures fine pressure changes
• IP40 enclosure and robust housing withstand typical site conditions
**Applications**
• Suitable for measuring pressure drops across HVAC components
• Ideal for performing duct traversals to calculate airflow volume
• Used for monitoring indoor versus outdoor pressure relationships
• Can be used to match ventilation to occupant loads
• Used with building fabric assessments to manage airflow and comfort
• Ideal for performing duct traversals to calculate airflow volume
• Used for monitoring indoor versus outdoor pressure relationships
• Can be used to match ventilation to occupant loads
• Used with building fabric assessments to manage airflow and comfort
What power options and runtimes are available for fieldwork?
The instrument operates from four AA batteries, delivering approximately 280 hours without the backlight and around 60 hours with the backlight active.
How many pressure connections does it offer and what type are they?
It includes two pressure ports configured for differential measurements and accepts a maximum overpressure of 10psi at each port.
What storage and environmental limits apply to the instrument?
Readings can be saved in internal memory up to 99 points
operating temperature is 0°C to 50°C and storage ranges from −40°C to +60°C with relative humidity up to 90% non‑condensing.
Which standards and approvals relate to its use in professional settings?
The unit meets CE requirements and electromagnetic compatibility standards in EN61326‑1, and vibration resilience to MIL‑PRF‑28800F Class 3.
Supplied with
Fluke 922 - two rubber hoses, wrist strap, 300mm Pitot tube, ToolPack hanging kit, hard carry case, 4 x AA Batteries and manual
相關連結
- Fluke 922 Differential Manometer, Max Pressure Measurement 6 psi
- RS PRO RS DPI Differential Manometer, Max Pressure Measurement 350 mbar
- Kane KANE3200 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 200 mbar
- KIMO Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 2000 mbar
- KIMO Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 500 mbar
- Testo 512-2 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 2000 mbar
- Testo 512-1 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 200 mbar
- RS PRO RS 3161-002-00-EX Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 2000 mbar