Honeywell Technologies 914CE Series Roller Plunger Limit Switch, SPDT, IP66, IP67, IP68, Die Cast Zinc Housing, 250V ac,

小計(1 件)*

TWD9,192.00

(不含稅)

TWD9,651.60

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 4 件從 2026年9月14日 起發貨
  • 加上 20 件從 2026年10月26日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD9,192.00

* 參考價格

RS庫存編號:
808-2729
製造零件編號:
914CE31-3
製造商:
Honeywell Technologies
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Honeywell Technologies

Product Type

Limit Switch

Actuator Type

Roller Plunger

Contact Configuration

SPDT

IP Rating

IP66, IP67, IP68

Housing Material

Die Cast Zinc

Contact Type

Snap Action

Terminal Type

Cable

Switching Current

5A

Series

914CE

Minimum Operating Temperature

0°C

Switching AC Voltage

250V ac

Switching DC Voltage

30V

Maximum Operating Temperature

105°C

Width

16mm

Standards/Approvals

CSA, cURus, UL, RoHS, CE, IEC, EN

Depth

44mm

Length

40mm

Hazardous Area Certification

No

Operating Force

22.2N

Mechanical Life

10000000Operations

Mounting Orientation

Vertical

COO (Country of Origin):
GB

Honeywell 914CE Series Limit Switch, 5A Switching Current, IP66/IP67/IP68 - 914CE31-3


This limit switch is a sealed actuator device designed to detect mechanical position changes in industrial systems. It employs a roller plunger actuator with snap-action contacts to provide reliable switching for automation and control tasks. The robust metal housing and high ingress protection ratings make it suitable for deployment where environmental sealing is required.

Features and Benefits:


• Die-cast zinc housing reduces corrosion and mechanical damage
• SPDT snap-action contact delivers distinct switching states
• 5A switching capacity supports moderate load circuits
• 250V AC and 30V DC ratings enable AC or DC installations
• IP66, IP67, IP68 sealing allows prolonged exposure to contaminants
• Mechanical life of 10 million operations minimises maintenance frequency

Applications


• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for position sensing on heavy-duty machinery in harsh environments
• Used with control panels requiring compact, sealed sensing devices
• Can be used for limit detection in outdoor automation equipment

What mounting orientations are supported for installation?


It is designed primarily for vertical mounting to ensure correct actuator alignment and intended operation.

How is wiring achieved for integration into control systems?


Connections are provided via a cable Terminal to simplify routing into remote junctions or control cabinets.

What operating force is required to actuate the mechanism?


The roller plunger requires an operating force of 22.2 N to change the contact state.

What thermal conditions can the switch tolerate during operation?


The device is specified to function up to a maximum temperature of 105 °C and not below 0 °C.

Which safety or conformity markings are present for regulatory acceptance?


It carries approvals including CSA, cURus, UL, RoHS, CE, IEC and EN to meet common industrial standards.

Approvals

UL, CSA.

Caution

Products in the 914CE series will only meet IP and NEMA standards when used in non-hazardous locations. They only satisfy the requirements when installed properly (as per instruction) and completely.

Warning

914CE limit switches are not emergency stop devices or safety devices. They must not be used in devices, applications and environments where injury can be incurred as a result of product failure.

Standards

IP Rating:
All models within the 914CE series meet IP65, IP66, IP67, IP68. This ensures that they are completely dust tight, offer protection against jets of water and can be immersed in water up to 3 m.

NEMA Rating:
Every 914CE limit switch also meets NEMA 1, 2, 3, 3R, 4, 6, 6P and 13 requirements.

Type 1: Allows for indoor use and offers a dregree of protection against access to harzardous parts by personnel. Enclosures that meet NEMA 1 also protect the enclosure against foreign solid obkects(such as indoor dirt).
Type 2: Allows for indoor use and provides a degree of protection against access to hazardous parts. The enclosures provide a degree of protection against foreign objects (such as falling dirt) and the ingress of water (light dripping or splashing).
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 3R: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures primarily provide ingress protection against water (such as rain, snow or sleet). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as the splashing, seepage and spraying of oil and non-corrosive coolants.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。