Telemecanique Sensors XCS Series Plunger Limit Switch, 1 NO/2 NC, IP67, IP66, Plastic Housing, 240V ac, 1.5A
- RS庫存編號:
- 766-1624
- 製造零件編號:
- XCSD3910P20
- 製造商:
- Telemecanique Sensors
小計(1 件)*
TWD3,897.00
(不含稅)
TWD4,091.85
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 5 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD3,897.00 |
* 參考價格
- RS庫存編號:
- 766-1624
- 製造零件編號:
- XCSD3910P20
- 製造商:
- Telemecanique Sensors
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Telemecanique Sensors | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| IP Rating | IP67, IP66 | |
| Contact Configuration | 1 NO/2 NC | |
| Housing Material | Plastic | |
| Contact Type | Snap Action | |
| Switching Current | 1.5A | |
| Terminal Type | M20 | |
| Series | XCS | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 70°C | |
| Width | 34mm | |
| Length | 89mm | |
| Standards/Approvals | IEC, EN, CSA, CE, UL, RoHS | |
| Depth | 35mm | |
| Hazardous Area Certification | No | |
| Conduit Entry | M20 x 1.5 | |
| Operating Force | 15N | |
| Mechanical Life | 15000000Cycles | |
| 選取全部 | ||
|---|---|---|
品牌 Telemecanique Sensors | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
IP Rating IP67, IP66 | ||
Contact Configuration 1 NO/2 NC | ||
Housing Material Plastic | ||
Contact Type Snap Action | ||
Switching Current 1.5A | ||
Terminal Type M20 | ||
Series XCS | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 70°C | ||
Width 34mm | ||
Length 89mm | ||
Standards/Approvals IEC, EN, CSA, CE, UL, RoHS | ||
Depth 35mm | ||
Hazardous Area Certification No | ||
Conduit Entry M20 x 1.5 | ||
Operating Force 15N | ||
Mechanical Life 15000000Cycles | ||
Telemecanique Sensors XCSD Series Limit Switch, IP67, 15N Operating Force - XCSD3910P20
This limit switch is a Compact mechanical device designed to detect position or end-of-travel in automated systems. It employs a plunger actuator housed in metal and is intended for use where a robust, sealed switching element is required across a wide ambient temperature range.
Features and Benefits:
• Plunger actuator delivers positive mechanical contact for accurate position detection
• Snap-action contacts provide quick transition to reduce contact bounce
• Contact arrangement 1 NO/2 NC allows versatile control logic configurations
• Switching capability 250 V dc and 240 V ac supports mixed-supply environments
• Mechanical life 15 000 000 cycles ensures extended service between replacements
• Ingress protection IP67 and IP66 offers protection against dust and water immersion
• Snap-action contacts provide quick transition to reduce contact bounce
• Contact arrangement 1 NO/2 NC allows versatile control logic configurations
• Switching capability 250 V dc and 240 V ac supports mixed-supply environments
• Mechanical life 15 000 000 cycles ensures extended service between replacements
• Ingress protection IP67 and IP66 offers protection against dust and water immersion
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for limit sensing on automated Gates and doors
• Used with hydraulic presses for position confirmation
• Can be used for safety interlocks in assembly automation
• Suitable for material handling equipment in wet conditions
• Ideal for limit sensing on automated Gates and doors
• Used with hydraulic presses for position confirmation
• Can be used for safety interlocks in assembly automation
• Suitable for material handling equipment in wet conditions
What Terminal and conduit provisions are provided for wiring?
The device uses a Terminal type with M20 conduit entry and thread M20x1.5 to accept standard gland fittings.
What electrical current can each contact handle during switching?
Each contact is rated for switching currents up to 1.5 A for typical control-circuit loads.
What operating force is required to actuate the plunger?
The plunger requires an operating force of 15 N to change state.
What ambient temperatures can the device operate within?
It is specified for operation from −25 °C up to 70 °C.
Which standards approvals are associated with the product?
Approvals include IEC, EN, CSA, CE, UL and RoHS.
Note
With the appropriate monitoring system and correctly wired these switches can reach safety category 4 conforming to EN/ISO 13849-1, PL e conforming to EN/ISO 13849-1, SIL 3 conforming to EN/IEC 61508.
Approvals
UL, CSA.
Standards
CSA C22-2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508.
相關連結
- Telemecanique Sensors XCSD Series Roller Plunger Interlock Switch IP67 Metal Housing 1.5A
- Telemecanique Sensors XCSD Series Rotary Safety Limit Switch IP66 Metal Housing 1.5A
- Telemecanique Sensors XCSD Series Rotary Safety Limit Switch IP66 Plastic Housing 1.5A
- Telemecanique Sensors XCSD Series Roller Lever Interlock Switch IP66 Metal Housing 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP68 IP66 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP67 IP68 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP66 IP68 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP67 IP66 240V ac, 1.5A
