Honeywell Technologies HDLS Series Roller Lever Limit Switch, SPDT, IP65, IP66, IP67, Stainless Steel Housing, 250V, 10A
- RS庫存編號:
- 691-7248
- 製造零件編號:
- LS2A4K
- 製造商:
- Honeywell
此圖片僅供參考,請參閲產品詳細資訊及規格
小計(1 件)*
TWD48,142.00
(不含稅)
TWD50,549.10
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 9 件從 2026年12月07日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD48,142.00 |
* 參考價格
- RS庫存編號:
- 691-7248
- 製造零件編號:
- LS2A4K
- 製造商:
- Honeywell
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| Contact Configuration | SPDT | |
| IP Rating | IP65, IP66, IP67 | |
| Housing Material | Stainless Steel | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Terminal Type | Screw | |
| Series | HDLS | |
| Minimum Operating Temperature | 12°C | |
| Switching DC Voltage | 24V dc | |
| Switching AC Voltage | 250V | |
| Maximum Operating Temperature | 121°C | |
| Width | 1.875in | |
| Standards/Approvals | RoHS | |
| Length | 122.96mm | |
| Depth | 2.437in | |
| Hazardous Area Certification | No | |
| Operating Force | 0.45Nm | |
| Mounting Orientation | Side | |
| Conduit Entry | 20 mm | |
| Mechanical Life | 50000000Operations | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
Contact Configuration SPDT | ||
IP Rating IP65, IP66, IP67 | ||
Housing Material Stainless Steel | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Terminal Type Screw | ||
Series HDLS | ||
Minimum Operating Temperature 12°C | ||
Switching DC Voltage 24V dc | ||
Switching AC Voltage 250V | ||
Maximum Operating Temperature 121°C | ||
Width 1.875in | ||
Standards/Approvals RoHS | ||
Length 122.96mm | ||
Depth 2.437in | ||
Hazardous Area Certification No | ||
Operating Force 0.45Nm | ||
Mounting Orientation Side | ||
Conduit Entry 20 mm | ||
Mechanical Life 50000000Operations | ||
Honeywell HDLS Series Limit Switch, 20mm Conduit Entry, Stainless Steel Housing - LS2A4K
This limit switch is a Compact mechanical position sensor designed for industrial control and automation environments. It provides a toggled electrical output when actuated by linear or rotary motion via a roller lever, and is constructed for use where ingress protection and robust switching behaviour are required.
Features and Benefits:
• Roller lever actuator delivers precise mechanical actuation and repeatability
• Single-pole double-throw contact offers flexible circuit switching
• Snap-action contacts ensure fast transition and reduced contact bounce
• Stainless-steel housing resists corrosion in harsh surroundings
• IP67 enclosure rating allows operation in wet or dusty locations
• Mechanical durability rated to 10 million cycles for long service life
• Single-pole double-throw contact offers flexible circuit switching
• Snap-action contacts ensure fast transition and reduced contact bounce
• Stainless-steel housing resists corrosion in harsh surroundings
• IP67 enclosure rating allows operation in wet or dusty locations
• Mechanical durability rated to 10 million cycles for long service life
Applications
• Suitable for conveyor end-of-travel detection in material-handling systems
• Ideal for machine-tool limit sensing in metalworking equipment
• Used with automated packaging lines for position verification
• Can be used for safety interlocks on industrial doors and guards
• Used for actuator end-stop detection in valve assemblies
• Ideal for machine-tool limit sensing in metalworking equipment
• Used with automated packaging lines for position verification
• Can be used for safety interlocks on industrial doors and guards
• Used for actuator end-stop detection in valve assemblies
What electrical connection method is provided for panel wiring?
Termination is via screw terminals that accept standard industrial conductors for secure connections.
What range of ambient temperatures can it withstand during operation?
The device can operate at temperatures down to −12°C and up to 121°C without impairing switching function.
How is the unit routed for conduit or cable entry?
A 20mm conduit entry is provided to accommodate standard conduit fittings for protected cable routing.
What mounting orientation is recommended for installation?
It is designed for side mounting to align the actuator with motion axes in confined assemblies.
Approvals
UL, CSA.
Standards
IP65, IP66, IP67
HDLS switches have a IP65, IP66 and IP67 rating. This means they are dust-tight and offer protection against water jets, heavy seas and the effects of immersion.
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
Type 1: Enclosures that meet Type 1 are for indoor use, and provide some limited protection for the enclosed equipment.
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4X: Allows for indoor our outdoor use and provides some ptoection against windust dust and rain, corroision, splashing water and hose directed water.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 12: Limit switches that meet Type 12 requirements provide limited protection against dust, falling dirt and non-corrosive liquids.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as spraying splashing and seepage of oil and non-corrosive coolants."
HDLS switches have a IP65, IP66 and IP67 rating. This means they are dust-tight and offer protection against water jets, heavy seas and the effects of immersion.
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
Type 1: Enclosures that meet Type 1 are for indoor use, and provide some limited protection for the enclosed equipment.
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4X: Allows for indoor our outdoor use and provides some ptoection against windust dust and rain, corroision, splashing water and hose directed water.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 12: Limit switches that meet Type 12 requirements provide limited protection against dust, falling dirt and non-corrosive liquids.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as spraying splashing and seepage of oil and non-corrosive coolants."
相關連結
- Honeywell Technologies HDLS Series Roller Lever Limit Switch IP67 600V
- Honeywell Technologies HDLS Series Adjustable Roller Lever Limit Switch IP67
- Honeywell Technologies HDLS Series Roller Lever Limit Switch IP65 IP67 600V ac,
- Honeywell Technologies HDLS Series Roller Lever Limit Switch IP67 240V ac,
- Honeywell Technologies HDLS Series Plunger Limit Switch IP67 240V ac, 10A
- Honeywell Technologies HDLS Series Rod Limit Switch IP67 24V ac, 10A
- Honeywell Technologies HDLS Series Limit Switch for Use with HDLS Series
- Honeywell Technologies Roller Lever Limit Switch IP67 Plastic Housing 10A