Omron D4n Series Roller Plunger Safety Limit Switch, 1 NO/2 NC, IP67, 240V ac, 2.5A
- RS庫存編號:
- 265-5183
- 製造零件編號:
- D4N-9132
- 製造商:
- Omron
小計(1 件)*
TWD3,012.00
(不含稅)
TWD3,162.60
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年12月25日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD3,012.00 |
* 參考價格
- RS庫存編號:
- 265-5183
- 製造零件編號:
- D4N-9132
- 製造商:
- Omron
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Omron | |
| Actuator Type | Roller Plunger | |
| Product Type | Safety Limit Switch | |
| Contact Configuration | 1 NO/2 NC | |
| IP Rating | IP67 | |
| Switching Current | 2.5A | |
| Terminal Type | M12 Connector | |
| Series | D4n | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | CCC, CSA, EN (TÜV) | |
| Hazardous Area Certification | No | |
| Mechanical Life | 15000000Cycles | |
| Conduit Entry | M12 | |
| 選取全部 | ||
|---|---|---|
品牌 Omron | ||
Actuator Type Roller Plunger | ||
Product Type Safety Limit Switch | ||
Contact Configuration 1 NO/2 NC | ||
IP Rating IP67 | ||
Switching Current 2.5A | ||
Terminal Type M12 Connector | ||
Series D4n | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals CCC, CSA, EN (TÜV) | ||
Hazardous Area Certification No | ||
Mechanical Life 15000000Cycles | ||
Conduit Entry M12 | ||
Omron D4n Series Safety Limit Switch, IP67, 250V DC Switching Voltage - D4N-9132
This safety limit switch is a compact, industrial actuator device designed to detect mechanical position changes and provide electrical switching in control circuits. It operates with a roller plunger actuator and is suited to indoor machine safety and general limit detection duties where a direct-opening contact mechanism and IP67 protection are required. The unit accommodates an M12 conduit entry and connector option, and is intended for environments requiring a wide operating temperature range and recognised approvals.
Features and Benefits:
• IP67 protection maintains enclosure sealing against dust and water
• Mechanical life 15,000,000 cycles reduces replacement frequency
• Contact arrangement 1NO/2NC offers versatile control logic
• Switching capacity 250V DC and 240V AC supports mixed loads
• Rated switching current 2.5A handles moderate current circuits
• Operating temperature range −30°C to 70°C copes with varied conditions
• Mechanical life 15,000,000 cycles reduces replacement frequency
• Contact arrangement 1NO/2NC offers versatile control logic
• Switching capacity 250V DC and 240V AC supports mixed loads
• Rated switching current 2.5A handles moderate current circuits
• Operating temperature range −30°C to 70°C copes with varied conditions
Applications
• Suitable for machine guard position monitoring in production lines
• Ideal for lift safety interlock compliance tasks
• Used with conveyor end-stop detection and process sequencing
• Can be used for safety door position sensing in factories
• Suitable for automated packaging position feedback systems
• Ideal for lift safety interlock compliance tasks
• Used with conveyor end-stop detection and process sequencing
• Can be used for safety door position sensing in factories
• Suitable for automated packaging position feedback systems
Which terminals provide the direct-opening safety function?
The NC contact terminals include a direct-opening mechanism that forcibly separates contacts even when metal deposition occurs.
What electrical protection is recommended for short-circuit conditions?
A 10 A fuse type gI or gG compliant with IEC 269 is specified for short-circuit protection in series with the switch.
How should connectors be fitted to preserve IP67 sealing?
Use recommended connectors with screw length not exceeding 9 mm and tighten the socket until no gap remains to maintain the rated degree of protection.
What limitations apply to outdoor or harsh chemical environments?
The device is intended for indoor use only and must not be used where hazardous gases, solvents, or continuous splashing occur as head contamination may cause malfunction.
How does contact durability compare between mechanical and electrical operation?
Mechanical durability is rated at 15,000,000 operations while electrical durability varies by load, for example, 500,000 operations for a resistive 3 A at 250 VAC load.
相關連結
- Omron D4n Series Plunger Limit Switch IP67 240V
- Omron D4n Series Roller Plunger Limit Switch IP67 240V, 10A
- Omron D4n Series Roller Plunger Limit Switch IP67 240V, 10A
- Omron D4n Series Top Plunger Safety Limit Switch IP67 240V, 10A
- Omron D4n Series Roller Arm Lever Safety Limit Switch IP67 240V ac, 2.5A
- Omron D4n Series Rod Limit Switch IP67 240V ac, 2.5A
- Omron D4n Series Plunger Limit Switch IP67, 250V ac
- Omron D4n Series Roller Plunger Safety Limit Switch IP67