Honeywell Technologies E7 Series Pin Plunger Limit Switch, SPDT, IP65, Die Cast Zinc Housing, 240V ac, 10A
- RS庫存編號:
- 217-7128
- 製造零件編號:
- DTE7-2RN-PG
- 製造商:
- Honeywell
小計(1 件)*
TWD19,552.00
(不含稅)
TWD20,529.60
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 2 件準備從其他地點送貨
- 加上 50 件從 2026年9月21日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD19,552.00 |
* 參考價格
- RS庫存編號:
- 217-7128
- 製造零件編號:
- DTE7-2RN-PG
- 製造商:
- Honeywell
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell | |
| Actuator Type | Pin Plunger | |
| Product Type | Limit Switch | |
| IP Rating | IP65 | |
| Contact Configuration | SPDT | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | Threaded Conduit | |
| Switching Current | 10A | |
| Series | E7 | |
| Minimum Operating Temperature | -30°C | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | EN/IEC 60947-5-1, CE, CSA file 15775 (BZ prefix only) | |
| Hazardous Area Certification | No | |
| Operating Force | 1389g | |
| Conduit Entry | 0.5 to 14 NPSM | |
| Mounting Orientation | Diagonal Side | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell | ||
Actuator Type Pin Plunger | ||
Product Type Limit Switch | ||
IP Rating IP65 | ||
Contact Configuration SPDT | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type Threaded Conduit | ||
Switching Current 10A | ||
Series E7 | ||
Minimum Operating Temperature -30°C | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals EN/IEC 60947-5-1, CE, CSA file 15775 (BZ prefix only) | ||
Hazardous Area Certification No | ||
Operating Force 1389g | ||
Conduit Entry 0.5 to 14 NPSM | ||
Mounting Orientation Diagonal Side | ||
Honeywell Limit Switch, Pin Plunger Actuator, 680g Operating Force - DTE7-2RN-PG
This limit switch provides a robust means of detecting position changes and controlling circuits in industrial installations. Constructed for side-diagonal mounting, it employs a pin-plunger actuator and is intended for use where discrete switching is required under mechanical motion or presence detection. The enclosure gives environmental protection suitable for many factory and field settings.
Features and Benefits:
• Die cast aluminium housing delivers corrosion-resistant durability
• IP65 sealed enclosure resists dust and low-pressure water jets
• SPDT snap-action contacts enable Rapid make-and-break switching
• Rated for 10A at AC applications to handle moderate loads
• 250V DC switching capability supports DC control circuits
• Operating force of 680g ensures consistent actuation threshold
• IP65 sealed enclosure resists dust and low-pressure water jets
• SPDT snap-action contacts enable Rapid make-and-break switching
• Rated for 10A at AC applications to handle moderate loads
• 250V DC switching capability supports DC control circuits
• Operating force of 680g ensures consistent actuation threshold
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for actuator position sensing in automated valves
• Used for safety cut-off sensing on packaging machinery
• Can be used for limit detection in material handling equipment
• Suitable for integration in control panels requiring threaded conduit entry
• Ideal for actuator position sensing in automated valves
• Used for safety cut-off sensing on packaging machinery
• Can be used for limit detection in material handling equipment
• Suitable for integration in control panels requiring threaded conduit entry
What conduit Interface does it provide for wiring?
The unit accepts threaded conduit connections sized 0.5-14 NPSM for secure cable entry.
How should it be mounted to align with mechanical linkages?
It is designed for diagonal side mounting to match common actuator geometries and reduce linkage stress.
What standards underpin its electrical switching design?
The switch conforms to EN/IEC 60947-5-1 functional switching requirements and carries relevant safety approvals.
What temperature range can it tolerate during operation?
It is specified to operate from a minimum of -30°C up to a maximum of 70°C without performance degradation.
相關連結
- Honeywell E7 Series Plunger Limit Switch IP50 480V ac, 15A
- Honeywell BZE6 Series Pin Plunger Limit Switch IP66 600V
- Honeywell BAF Series Plunger Limit Switch IP3 Zinc Die Cast Housing 20A
- Honeywell DTE6 Series Plunger Limit Switch IP66 250V ac, 10A
- Honeywell BAF Series Top Plunger Limit Switch Die Cast Aluminium Housing 20A
- Honeywell E7 Series Coil Spring Limit Switch IP65, Die Cast Zinc Housing
- Honeywell E7 Series Roller Lever Limit Switch IP50 480V ac, 15A
- Honeywell Top Plunger Limit Switch IP66, Die Cast Zinc Epoxy Coated Housing