Honeywell Technologies GLA Series Plunger Limit Switch, 1 NC/1 NO, IP67, Zinc Housing, 600V ac, 6A
- RS庫存編號:
- 186-8188
- Distrelec 貨號:
- 303-44-317
- 製造零件編號:
- GLAC01B
- 製造商:
- Honeywell Technologies
小計(1 件)*
TWD8,284.00
(不含稅)
TWD8,698.20
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 + | TWD8,284.00 |
* 參考價格
- RS庫存編號:
- 186-8188
- Distrelec 貨號:
- 303-44-317
- 製造零件編號:
- GLAC01B
- 製造商:
- Honeywell Technologies
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell Technologies | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| IP Rating | IP67 | |
| Contact Configuration | 1 NC/1 NO | |
| Housing Material | Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 600V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Depth | 42mm | |
| Width | 42mm | |
| Length | 145.8mm | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Hazardous Area Certification | No | |
| Mechanical Life | 15000000Operations | |
| Operating Force | 16N | |
| Conduit Entry | 20 mm | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell Technologies | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
IP Rating IP67 | ||
Contact Configuration 1 NC/1 NO | ||
Housing Material Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 600V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Depth 42mm | ||
Width 42mm | ||
Length 145.8mm | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Hazardous Area Certification No | ||
Mechanical Life 15000000Operations | ||
Operating Force 16N | ||
Conduit Entry 20 mm | ||
- COO (Country of Origin):
- GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, IP67 - GLAC01B
This limit switch is a plunger-operated device designed for position sensing and circuit interruption in industrial control systems. It provides snap-action contacts for Rapid switching and is intended for use in automation, electrical and mechanical installations where a robust, sealed actuator is required.
Features and Benefits:
• IP67 rating ensures protection in wet and dusty environments
• Snap-action contacts deliver quick, reliable switching at load
• 600V AC switching capability supports high-voltage control circuits
• 6A current rating handles moderate control and signalling loads
• Operating temperature range down to -25°C and up to 85°C allows wide thermal use
• Mechanical endurance rated at 15,000,000 operations reduces maintenance frequency
• Snap-action contacts deliver quick, reliable switching at load
• 600V AC switching capability supports high-voltage control circuits
• 6A current rating handles moderate control and signalling loads
• Operating temperature range down to -25°C and up to 85°C allows wide thermal use
• Mechanical endurance rated at 15,000,000 operations reduces maintenance frequency
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for machine tool limit sensing in metalworking facilities
• Used with motor starters for safety interlock feedback
• Can be used for position feedback in packaging equipment
• Suitable for gate and barrier open/close monitoring in access control
• Ideal for machine tool limit sensing in metalworking facilities
• Used with motor starters for safety interlock feedback
• Can be used for position feedback in packaging equipment
• Suitable for gate and barrier open/close monitoring in access control
What conduit connection does it accept for wiring?
It accepts an M20 conduit entry to accommodate standard industrial cabling.
How are the electrical terminals configured?
Terminals provide a single normally closed and a single normally open contact for flexible control logic.
What material protects the housing against corrosion?
The enclosure is finished with an electrostatic epoxy-coated zinc treatment for enhanced surface protection.
Is it certified for recognised safety standards?
It carries approvals from UL, CSA, CE and CCC for international acceptance.
What actuation force is required to operate the plunger?
The plunger requires an operating force of 16 N to activate the switching mechanism.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
相關連結
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A