Honeywell Technologies GLA Series Plunger Limit Switch, 1 NC/1 NO, IP67, Die Cast Zinc Housing, 600V ac, 6A
- RS庫存編號:
- 186-8188
- Distrelec 貨號:
- 303-44-317
- 製造零件編號:
- GLAC01B
- 製造商:
- Honeywell Technologies
小計(1 件)*
TWD8,077.00
(不含稅)
TWD8,480.85
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 5 件從 2026年9月21日 起發貨
- 加上 12 件從 2026年12月14日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD8,077.00 |
* 參考價格
- RS庫存編號:
- 186-8188
- Distrelec 貨號:
- 303-44-317
- 製造零件編號:
- GLAC01B
- 製造商:
- Honeywell Technologies
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell Technologies | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| IP Rating | IP67 | |
| Contact Configuration | 1 NC/1 NO | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Terminal Type | M20 | |
| Series | GLA | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Depth | 42mm | |
| Length | 145.8mm | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Width | 42mm | |
| Hazardous Area Certification | No | |
| Conduit Entry | 20 mm | |
| Operating Force | 16N | |
| Mechanical Life | 15000000Operations | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell Technologies | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
IP Rating IP67 | ||
Contact Configuration 1 NC/1 NO | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Terminal Type M20 | ||
Series GLA | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Depth 42mm | ||
Length 145.8mm | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Width 42mm | ||
Hazardous Area Certification No | ||
Conduit Entry 20 mm | ||
Operating Force 16N | ||
Mechanical Life 15000000Operations | ||
- COO (Country of Origin):
- GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, IP67 - GLAC01B
This limit switch is a plunger-operated device designed for position sensing and circuit interruption in industrial control systems. It provides snap-action contacts for Rapid switching and is intended for use in automation, electrical and mechanical installations where a robust, sealed actuator is required.
Features and Benefits:
• IP67 rating ensures protection in wet and dusty environments
• Snap-action contacts deliver quick, reliable switching at load
• 600V AC switching capability supports high-voltage control circuits
• 6A current rating handles moderate control and signalling loads
• Operating temperature range down to -25°C and up to 85°C allows wide thermal use
• Mechanical endurance rated at 15,000,000 operations reduces maintenance frequency
• Snap-action contacts deliver quick, reliable switching at load
• 600V AC switching capability supports high-voltage control circuits
• 6A current rating handles moderate control and signalling loads
• Operating temperature range down to -25°C and up to 85°C allows wide thermal use
• Mechanical endurance rated at 15,000,000 operations reduces maintenance frequency
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for machine tool limit sensing in metalworking facilities
• Used with motor starters for safety interlock feedback
• Can be used for position feedback in packaging equipment
• Suitable for gate and barrier open/close monitoring in access control
• Ideal for machine tool limit sensing in metalworking facilities
• Used with motor starters for safety interlock feedback
• Can be used for position feedback in packaging equipment
• Suitable for gate and barrier open/close monitoring in access control
What conduit connection does it accept for wiring?
It accepts an M20 conduit entry to accommodate standard industrial cabling.
How are the electrical terminals configured?
Terminals provide a single normally closed and a single normally open contact for flexible control logic.
What material protects the housing against corrosion?
The enclosure is finished with an electrostatic epoxy-coated zinc treatment for enhanced surface protection.
Is it certified for recognised safety standards?
It carries approvals from UL, CSA, CE and CCC for international acceptance.
What actuation force is required to operate the plunger?
The plunger requires an operating force of 16 N to activate the switching mechanism.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
相關連結
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A