規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Telemecanique Sensors | |
| Product Type | Safety Limit Switch | |
| Actuator Type | Roller Plunger | |
| IP Rating | IP66, IP67, IP68 | |
| Contact Configuration | 2 NO/2 NC | |
| Housing Material | Metal | |
| Contact Type | Snap Action | |
| Terminal Type | Pre-Cabled | |
| Switching Current | 6A | |
| Series | XCSM | |
| Switching DC Voltage | 300V dc | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 400V ac | |
| Maximum Operating Temperature | 70°C | |
| Width | 30mm | |
| Standards/Approvals | CSA, UL | |
| Length | 70mm | |
| Depth | 16mm | |
| Hazardous Area Certification | No | |
| Conduit Entry | M20 | |
| Mechanical Life | 10000000Cycles | |
| Operating Force | 7N | |
| Mounting Orientation | Horizontal | |
| 選取全部 | ||
|---|---|---|
品牌 Telemecanique Sensors | ||
Product Type Safety Limit Switch | ||
Actuator Type Roller Plunger | ||
IP Rating IP66, IP67, IP68 | ||
Contact Configuration 2 NO/2 NC | ||
Housing Material Metal | ||
Contact Type Snap Action | ||
Terminal Type Pre-Cabled | ||
Switching Current 6A | ||
Series XCSM | ||
Switching DC Voltage 300V dc | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 400V ac | ||
Maximum Operating Temperature 70°C | ||
Width 30mm | ||
Standards/Approvals CSA, UL | ||
Length 70mm | ||
Depth 16mm | ||
Hazardous Area Certification No | ||
Conduit Entry M20 | ||
Mechanical Life 10000000Cycles | ||
Operating Force 7N | ||
Mounting Orientation Horizontal | ||
Telemecanique Sensors XCSM Series Safety Limit Switch, IP66/IP67/ IP68, 2 NO/2 NC Contact Configuration - XCSM4102L5
This safety limit switch provides a robust electromechanical means of detecting actuator travel and initiating machine safety or control responses in industrial environments. It uses a roller plunger actuator to convert mechanical motion into snap-action contact changes, intended for horisontal mounting on equipment where ingress protection and dependable switching are required.
Features and Benefits:
• Metal housing resists mechanical damage for extended service life
• 2NO/2NC snap action contacts deliver clear make/break signals
• Switching capability up to 300V DC and 6A supports varied circuits
• Pre-cabled design with M20 conduit entry simplifies installation
• Rated for 10000000 cycles for long-term operational duty
• Operates between -25°C and 70°C for broad environmental range
• 2NO/2NC snap action contacts deliver clear make/break signals
• Switching capability up to 300V DC and 6A supports varied circuits
• Pre-cabled design with M20 conduit entry simplifies installation
• Rated for 10000000 cycles for long-term operational duty
• Operates between -25°C and 70°C for broad environmental range
Applications
• Suitable for conveyor end-of-travel detection in factories
• Ideal for guarding interlocks on assembly-line machinery
• Used for position sensing on packaging equipment
• Can be used for safety monitoring of industrial presses
• Ideal for guarding interlocks on assembly-line machinery
• Used for position sensing on packaging equipment
• Can be used for safety monitoring of industrial presses
How is the switch mounted and routed on machinery?
It is designed for horisontal mounting and features an M20 conduit entry for secure cable routing and conduit connection.
What contact arrangement is provided for safety circuits?
It offers two normally open and two normally closed contacts arranged for snap-action switching to facilitate safety and control circuit layouts.
How does the unit perform in wet or dusty environments?
The enclosure meets high ingress protection levels enabling operation in environments requiring IP66, IP67 and IP68 resistance to dust and water.
What electrical standards does it comply with for use in installations?
The unit has approvals from recognised North American safety bodies to meet specified installation requirements.
What actuation force should be expected during use?
The roller plunger requires an operating force of 7 N to actuate the contact mechanism.
相關連結
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP68 IP66 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Roller Plunger Safety Limit Switch IP68 IP66 240V
- Telemecanique Sensors XCSM Series Roller Plunger Safety Limit Switch IP66 IP68 400V
- Telemecanique Sensors XCSM Series Roller Plunger Safety Limit Switch IP66 IP68 240V
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP66 IP68 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP67 IP68 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP67 IP66 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Roller Plunger Limit Switch IP66 IP68 240V ac, 1.5A