SICK MICS3 Series Laser Scanner Laser Scanner, 5.5 m Max Range

小計(1 件)*

TWD313,402.00

(不含稅)

TWD329,072.10

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2027年2月15日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD313,402.00

* 參考價格

RS庫存編號:
285-4117
製造零件編號:
MICS3-CBAZ55EN1P01 / 1103950
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Laser Scanner

Series

MICS3

Component Type

Laser Scanner

Maximum Scanning Distance

5.5m

Safety Type

3

Standards/Approvals

CE, cULus, UKCA

Maximum Response Time

95ms

Terminal Type

M12

Hazardous Area Certification

No

Protective Height

5.5m

Length

111.1mm

Height

150.7mm

Peak Wavelength

845nm

Width

112mm

COO (Country of Origin):
DE

SICK MICS3 Series Laser Scanner, 5.5m Maximum Scanning Distance, 95ms Maximum Response Time - MICS3-CBAZ55EN1P01 / 1103950


This laser scanner is a Compact sensing device designed for proximity detection and area monitoring in industrial settings. It operates as a safety-rated unit delivering Rapid response for dynamic environments. The product is suitable for integration where controlled scanning range and recognised approvals are required.

Features and Benefits:


• 95 MS maximum response time for prompt hazard detection
• 5.5 m maximum scanning distance for extended coverage
• 845 nm Peak Wavelength for consistent optical performance
• Safety Type 3 classification for controlled stop applications
• M12 Terminal simplifies connection to automation networks

Applications


• Suitable for pedestrian flow monitoring in busy zones
• Ideal for perimeter protection in manufacturing cells
• Used with safety controllers in access control systems
• Can be used for pallet detection on conveyor lines
• Suitable for robot workcell intrusion detection

What protective height does it support for safeguarding zones?


It provides a protective height of 5.5 m allowing vertical coverage suitable for multi-level detection.

Which approvals permit its use in regulated installations?


It carries CE, cULus and UKCA approvals enabling deployment within applicable jurisdictions.

What Terminal Interface is provided for electrical connection?


A circular M12 Terminal is fitted for signal and power interfacing.

Is the unit certified for use in hazardous atmospheres?


It does not have hazardous-area certification and is not rated for classified explosive environments.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。