SICK deTec2 Core Series Light Curtain Sender, 30 mm Resolution

小計(1 件)*

TWD24,545.00

(不含稅)

TWD25,772.25

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月22日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD24,545.00

* 參考價格

RS庫存編號:
913-9277
製造零件編號:
C2C-SA12030A10000
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Light Curtain

Series

deTec2 Core

Beam Resolution

30mm

Component Type

Sender

Safety Type

Type 2

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

1.2m

Maximum Protective Width

15m

Maximum Supply Voltage

24V dc

Minimum Scanning Distance

0μm

Maximum Scanning Distance

12m

Width

34mm

Maximum Response Time

12ms

Length

1.213m

Height

30.7mm

Terminal Type

5-Pin M12

豁免

COO (Country of Origin):
DE

SICK deTec2 Core Series Light Curtain, 1200mm Protective Height, 15m Protective Width - C2C-SA12030A10000


This light curtain is a sender module intended for industrial safety applications, providing an optically synchronised protective field for machine guarding in standard industrial environments. It operates from a 24V DC supply and is designed to detect intrusions across a tall safety zone, supporting safe stop functions and external monitoring when paired with compatible receivers and safety relays.

Features and Benefits:


• 30mm beam resolution for precise intrusion detection
• 12ms maximum response time for Rapid detection
• 12m maximum scanning distance for extended reach
• Optical synchronisation to prevent cross-talk between devices
• 24V DC supply with ≤10% ripple for stable operation

Applications


• Suitable for machine guarding on production lines
• Ideal for access protection on automated conveyors
• Used with safety relays for restart interlock circuits
• Can be used for perimeter protection of workstations
• Suitable for integration with dual-channel safety controls

What safety classification does it meet?


It conforms to Type 2 safety requirements and attains Performance Level PLc and SIL1.

How does it behave in the event of a detected fault?


A fault forces at least one output to the OFF state and can trigger lock-out for cross-circuit or short-circuit faults.

What environmental conditions can it withstand?


It is rated IP65/IP67, operates from -30°C to +55°C, and tolerates 15%-95% non-condensing humidity.

What mechanical robustness is specified for vibration and shock?


It meets vibration resistance of 5 to 150Hz, 3.5mm/1g and shock resistance of 15g/6ms.

How is the device connected electrically?


The sender uses a 5-pin M12 plug with a 150mm cable tail and a 4.3mm cable diameter.

Standards

Type 2 IEC 61496, SIL1 IEC 61508, PL c EN ISO 13849.