SICK C40E Series Light Curtain Receiver, 40 mm Resolution

小計(1 件)*

TWD108,000.00

(不含稅)

TWD113,400.00

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年10月29日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD108,000.00

* 參考價格

RS庫存編號:
285-0972
製造零件編號:
C40E-0904CB010
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Light Curtain

Series

C40E

Beam Resolution

40mm

Component Type

Receiver

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

900mm

Maximum Supply Voltage

24V

Maximum Scanning Distance

21m

Width

40mm

Length

48mm

Height

1.03m

Maximum Response Time

11ms

COO (Country of Origin):
DE

SICK C40E Series Light Curtain, 900mm Protective Height, 24V Supply Voltage - C40E-0904CB010


This light curtain is a safety sensor designed for industrial protection of personnel and machinery. It operates as a receiver within a safety light curtain system for normal industrial environments, providing an uninterrupted protective field to detect intrusions and initiate safe shutdowns. The unit is built for use with compatible control modules and supports optical synchronisation for multi-unit setups.

Features and Benefits:


• 21m scanning range enables long-reach hazard detection
• 11 MS response time reduces stopping distance for hazards
• 40mm beam resolution detects moderate-sized obstructions
• Type 4 safety achieves high-level functional safety
• 24V supply supports common industrial power architectures

Applications


• Suitable for machine guarding in production lines
• Used with safety switching amplifiers for output control
• Ideal for packaging and material-handling protection zones
• Can be used in systems requiring optical synchronisation

What safety performance levels does it meet?


It conforms to Type 4 safety with SIL 3, Category 4 and PL e performance.

How are outputs implemented for safety integration?


It provides two short-circuit-protected PNP OSSDs with cross-circuit monitoring and ≤ 500mA per output.

Which environmental limits affect installation?


It operates between 0°C and +55°C with IP65 protection and non‑condensing humidity 15%-95%.

How is configuration and diagnostics performed?


A female M8 4-pin connector is used and configuration is via PC with dedicated CDS software.