Omron F3SG-SRB Series Light Curtain Receiver, Sender, 50 Beam(s), 25 mm Resolution

小計(1 件)*

TWD68,824.00

(不含稅)

TWD72,265.20

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年11月03日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD68,824.00

* 參考價格

RS庫存編號:
215-5141
製造零件編號:
F3SG-4SRB1000-25-F
製造商:
Omron
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Omron

Product Type

Light Curtain

Series

F3SG-SRB

Beam Resolution

25mm

Component Type

Receiver, Sender

Safety Type

Type 4

Standards/Approvals

No

Number of Beams

50

Protective Height

1m

Maximum Supply Voltage

28.8V

Maximum Protective Width

20m

Minimum Scanning Distance

0.3m

Maximum Scanning Distance

20m

Length

1m

Maximum Response Time

13ms

Width

32mm

Height

1m

Omron F3SG-SRB Series Light Curtain, 1m Protective Height, 50 Beams - F3SG-4SRB1000-25-F


This light curtain is a safety sensing device designed to detect intrusion into hazardous zones and stop machinery operations where human presence is undesirable. It functions as a receiver within a protective safety system, providing short-range detection across a 1m protective height and supporting industrial guarding tasks where rapid interruption of hazardous motion is required.

Features and Benefits:


• 50 beams provide dense detection and reduce bypass risk
• 25mm beam resolution enables fine object discrimination
• 0.3m minimum scanning distance permits close-proximity protection
• 20m maximum scanning distance supports long-range coverage
• 13 ms maximum response time reduces stopping delay for machinery
• 28.8V maximum supply simplifies integration with low-voltage systems

Applications


• Suitable for safeguarding robotic workcells with close access
• Ideal for conveyor end-of-line personnel protection
• Used with press and stamping machines for area intrusion detection
• Can be used for perimeter monitoring of production cells
• Suitable for short-range access control in assembly stations

How does the device behave when multiple beams are interrupted?


When one or more of the 50 optical paths are broken, the receiver reports an interruption condition and outputs a safety signal within the specified 13 ms response window to initiate machine stoppage.

What installation clearance is required between sensor and object?


The sensor is rated to operate from a minimum separation of 0.3 m, so mounting should ensure the nearest protected zone boundary is at or beyond this short-range limit.

Which supply constraints must be observed during wiring?


The unit must be powered within its maximum supply voltage rating of 28.8V to maintain specified detection and response characteristics.

How fine are the sensing increments for distinguishing small targets?


The optical spacing delivers 25mm resolution, allowing detection of relatively small intrusions across the protective height.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。