Omron F3SG-R Easy Series Light Curtain Sender, Receiver, 68 Beam(s), 30 mm Resolution

小計(1 件)*

TWD61,874.00

(不含稅)

TWD64,967.70

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 從 2026年12月30日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD61,874.00

* 參考價格

RS庫存編號:
215-5092
製造零件編號:
F3SG-2RE1390P30
製造商:
Omron
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Omron

Product Type

Light Curtain

Series

F3SG-R Easy

Beam Resolution

30mm

Component Type

Sender, Receiver

Safety Type

Type 2

Standards/Approvals

No

Number of Beams

68

Protective Height

1.39m

Maximum Supply Voltage

24V

Maximum Protective Width

20m

Minimum Scanning Distance

300mm

Maximum Scanning Distance

20m

Maximum Response Time

9ms

Terminal Type

4-Pin M12 Connector

Omron F3SG-R Easy Series Light Curtain, 1.39m Protective Height, 68 Beams - F3SG-2RE1390P30


This light curtain is a safety sensor pair designed to protect access points in industrial automation by detecting intrusions across a monitored zone. It operates as a sender and receiver combination and is intended for integration into machinery safeguarding systems where rapid detection and signalling are required.

Features and Benefits:


• 68-beam array for fine object detection and reduced blind spots
• 30mm beam spacing enabling precise presence detection
• 9ms maximum response time for prompt hazard interruption
• 0.3-20m operational range permitting flexible installation distances
• 24V supply compatibility with common control systems
• 4-pin connector terminal simplifies wiring and connection

Applications


• Suitable for safeguarding moving-press access openings
• Ideal for perimeter protection on conveyor lines
• Used with pick-and-place stations to prevent hand intrusion
• Can be used for robot cell access monitoring
• Employed in packaging machinery guarding setups

What component roles are included in the device pairing?


It comprises a dedicated sender and a matched receiver that work together to form the protective light screen.

How wide an area can the system monitor in a single installation?


The unit supports a maximum protective width of 20m when deployed in a single-screen configuration.

Which safety classification applies to its performance category?


The equipment conforms to a Type 2 safety designation suitable for applications requiring intermediate risk-reduction measures.

What minimum distance must be maintained from the protected object for correct detection?


The minimum scanning distance required for reliable detection is 0.3m from the light curtain face.