Omron F3SG Series Light Curtain Receiver, Sender, 60 Beam(s), 14 mm Resolution

小計(1 件)*

TWD118,421.00

(不含稅)

TWD124,342.05

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年12月09日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD118,421.00

* 參考價格

RS庫存編號:
214-7607
製造零件編號:
F3SG-4RA0560-14
製造商:
Omron
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Omron

Product Type

Light Curtain

Series

F3SG

Beam Resolution

14mm

Component Type

Receiver, Sender

Safety Type

Type 4

Standards/Approvals

No

Number of Beams

60

Protective Height

560mm

Maximum Supply Voltage

24V

Maximum Protective Width

10m

Minimum Scanning Distance

0.3m

Maximum Scanning Distance

10m

Maximum Response Time

13ms

Omron F3SG Series Light Curtain, 560mm Protective Height, 60 Beams - F3SG-4RA0560-14


This light curtain provides area protection for machinery by detecting intrusions across an optical beam array. Designed for industrial guarding, it comprises a separate sender and receiver pair and is intended for use where hazardous machine access must be monitored and interrupted.

Features and Benefits:


• 60 beams deliver dense detection for fine object sensing
• 14mm beam resolution enables detection of small cross-sections
• Type 4 safety classification supports high-risk applications
• 13ms maximum response time reduces stoppage latency
• 24V supply compatibility simplifies integration with control systems
• 0.3m to 10m scanning distance allows flexible installation ranges

Applications


• Suitable for safeguarding access to automated presses
• Ideal for perimeter protection on robotic cells
• Used with conveyor infeed zones requiring presence detection
• Can be used for protecting point-of-operation tooling
• Suitable for inspection stations where quick detection is needed

How many emitter/receiver units are required for a typical guarded opening?


The system uses a dedicated sender and receiver pair to create the protective curtain of beams.

What is the maximum lateral coverage possible in a single installation?


The device supports a protective width up to 10m for broad applications.

How close can the sensing start from the equipment edge?


Detection can begin at a minimum scanning distance of 0.3m from the unit.

How does beam count affect object discrimination?


A higher beam count increases vertical resolution, improving detection of narrow objects and reducing blind zones.