Endress+Hauser FTW33 Series Conductive Level Switch Level Switch, Threaded Mount, Vinyl Methyl Silicone, Housing 316L

小計(1 件)*

TWD14,474.00

(不含稅)

TWD15,197.70

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD14,474.00

* 參考價格

RS庫存編號:
267-9367
Distrelec 貨號:
303-84-154
製造零件編號:
FTW33-AA4MW5J
製造商:
Endress+Hauser
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Endress+Hauser

Device Type

Conductive Level Switch

Product Type

Level Switch

Mount Type

Threaded Mount

Housing Material

316L Stainless Steel

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

70°C

Maximum DC Voltage

30V dc

Maximum Pressure

25bar

Gasket Material

Vinyl Methyl Silicone

Standards/Approvals

CE mark

Hazardous Area Certification

No

Series

FTW33

COO (Country of Origin):
DE

Endress+Hauser FTW33 Series Level Switch, 25 Bar Maximum Pressure, 70°C Maximum Operating Temperature - FTW33-AA4MW5J


This conductive level switch detects liquid presence using an electrical conduction principle and is intended for industrial fluid monitoring. It is constructed for deployment via a threaded connection and is supplied with a 5m cable to connect to control systems. The housing is metal and suited to environments requiring corrosion resistance while operating across a wide ambient temperature range.

Features and Benefits:


• 316L stainless steel housing resists corrosion and prolongs service life
• Rated for 10 bar overpressure up to a maximum of 25 bar for pressurised vessels
• Operates from -40 to 70°C for broad temperature applications
• Low-current switching at 30V DC and 15 mA minimises power draw
• Ethylene propylene diene monomer gasket provides chemical sealing
• Non-hazardous-area design simplifies site classification handling

Applications


• Used for level detection in potable and process water tanks
• Suitable for monitoring liquid levels in pressurised vessels up to 25 bar
• Ideal for integration with control cabinets requiring low-voltage inputs
• Can be used for conductive-liquid detection where stainless steel wetted parts are necessary
• Used with industrial sensors where threaded mounting is preferred

What connection method is required for installation?


It uses a threaded mount to secure into tank ports or flanges, providing a straightforward mechanical attachment for inline or sidewall installation.

How does the sensor handle electrical interfacing?


The unit switches at low DC parameters and is compatible with low-current input circuits, using the supplied 5m cable for signal and power routing.

Is the unit suitable for use in classified hazardous zones?


The instrument is not certified for hazardous-area installation and should only be installed in non-classified locations or within appropriate protective enclosures.

What sealing material contacts process fluids?


The sealing element is made from EPDM, offering resistance to a range of aqueous media and maintaining a pressure-tight seal.