SICK LBV310 Series Vibrating Level Switch Vibrating Level Switch, Horizontal, Threaded, Vertical, ATEX, 2G Ex ia IIC
- RS庫存編號:
- 213-3265
- 製造零件編號:
- LBV310-XXAGDRKMX
- 製造商:
- SICK
小計(1 件)*
TWD27,952.00
(不含稅)
TWD29,349.60
(含稅)
訂單超過 $1,300.00 免費送貨
製造商存貨
- 準備從 2026年6月09日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD27,952.00 |
* 參考價格
- RS庫存編號:
- 213-3265
- 製造零件編號:
- LBV310-XXAGDRKMX
- 製造商:
- SICK
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | SICK | |
| Device Type | Vibrating Level Switch | |
| Product Type | Vibrating Level Switch | |
| Mount Type | Horizontal, Threaded, Vertical | |
| Housing Material | Plastic, Stainless Steel | |
| Cable Length | 1.5mm | |
| Minimum Operating Temperature | -50°C | |
| Maximum Operating Temperature | 150°C | |
| Maximum DC Voltage | 72V dc | |
| Maximum AC Voltage | 253V ac | |
| Maximum Current | 3A | |
| Maximum Pressure | 25bar | |
| Standards/Approvals | CE Certified | |
| Hazardous Area Certification | ATEX, 2G Ex ia IIC T6+ATEX II 1/2 D IP6X T | |
| Series | LBV310 | |
| 選取全部 | ||
|---|---|---|
品牌 SICK | ||
Device Type Vibrating Level Switch | ||
Product Type Vibrating Level Switch | ||
Mount Type Horizontal, Threaded, Vertical | ||
Housing Material Plastic, Stainless Steel | ||
Cable Length 1.5mm | ||
Minimum Operating Temperature -50°C | ||
Maximum Operating Temperature 150°C | ||
Maximum DC Voltage 72V dc | ||
Maximum AC Voltage 253V ac | ||
Maximum Current 3A | ||
Maximum Pressure 25bar | ||
Standards/Approvals CE Certified | ||
Hazardous Area Certification ATEX, 2G Ex ia IIC T6+ATEX II 1/2 D IP6X T | ||
Series LBV310 | ||
- COO (Country of Origin):
- DE
Overview
At a glance
Tough device design
Several housing materials and electrical outputs available
Immune to deposit formation
Commissioning without filling
Process temperature up to 250 °C
Very high repeatability
ATEX versions (1D/2D/1G/2G) available
Tube-extended version (LBV330) up to 6 m and rope extensions version (LBV320) up to 80 m available for vertical mounting
Your Benefit
Easy installation and commissioning, no calibration necessary
Easy operation and integration, saves time
Maintenance-free sensor, reduces downtime
Testing in place possible – no mounting required, which reduces installation time
Flexible and tough system for a multitude of applications
Solutions for vertically mounted switches in difficult installation conditions and surroundings
Level monitoring in dust hopper
Level monitoring in silos
Level monitoring in fuel tank
The rugged, reliable, and highly accurate vibrating level switches in the LBV300 product family signal full, empty, or demand states in bulk materials. The tuning fork reacts to changes in density, and thus operates independently of silo shape or the tank material used. The rugged stainless steel tuning fork is piezo-electrically energized and vibrates at its resonance frequency when it is covered by bulk materials. This change is detected and converted into a switching signal. While the LBV310 compact device is used for horizontal mounting and to signal full states, the LBV320 cable-extended switch and the LBV330 tube-extended switch are used for vertical mounting in silos and bridge sensing ranges of up to 80 m and 6 m respectively. With a wide variety of thread and flange connections, and several electronic variants, the LBV330 offers a solution for almost all applications, even in potentially explosive atmospheres.
Applications
Level measurement in the material container
Overfill protection for sawdust bunkers and silos
Level measurement in the material container
Overfill protection for aggregates and raw meal silos
Level monitoring in the coal hopper
Level monitoring in the dust hopper
Level monitoring in the cement silo
Overfill protection for coal bunkers/silos
Overfill protection for the lime silo
Ash hopper level monitoring in coal-fired power plants
Overfill protection for biomass bunkers and silos
Sorbent material storage silo
Overflow protection for biomass bunkers and silos (organic waste incineration)
Overflow protection when stocking reagents for flue gas purification
Ash hopper level monitoring
Level measurement during material handling
Silo levels at a blast furnace
Clogging in a compartment hopper
Dust silo filling level at a dust conveying system in the off-gas system
Level monitoring in bauxite or aluminum stores
Level monitoring in collection containers of electrolysis cell
相關連結
- SICK LBV310 Series Vibrating Level Switch Vibrating Level Switch Threaded 2G Ex ia IIC T6,
- SICK LBV310 Series Vibrating Level Switch Vibrating Level Switch Threaded ATEX, 2G Ex ia IIC T6
- Vega 1/2G ATEX II 1G Standard
- SICK LBV311 Series Vibrating Level Switch Vibrating Level Switch Threaded Ex
- Vega VEGAVIB 61 Series Vibrating Rod Level Switch Silicone, Housing Plastic
- SICK LBV311 Series Vibrating Level Switch Vibrating Level Switch Threaded 1 2D Ex tD IP66 T,
- SICK LFV200 Series Vibrating Level Switch Vibrating Level Switch Threaded Housing
- SICK LFV200 Series Vibrating Level Switch Vibrating Level Switch Threaded Housing Stainless