Siemens 3-Pole Panel Mount Non-Fused Switch Disconnector -, IP65, 16A, 8 kW

小計(1 件)*

TWD9,985.00

(不含稅)

TWD10,484.25

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 1 件準備從其他地點送貨
  • 加上 6 件從 2026年11月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD9,985.00

* 參考價格

RS庫存編號:
239-2617
製造零件編號:
3LD2017-0TK13
製造商:
Siemens
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Siemens

Number of Poles

3

Product Type

Non-Fused Switch Disconnector

Mount Type

Panel Mount

IP Rating

IP65

Handle Colour

Red, Yellow

Auxiliary Contacts Available

Yes

Series

3LD

Terminal Type

Box

Switching Current

16A

Switching Power

8kW

Padlock Compatibility

Yes

Switching AC Voltage

600V ac

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

55°C

Width

67mm

Depth

385mm

Length

75mm

Standards/Approvals

UL 60947-4-1, UL 508

Hazardous Area Certification

No

COO (Country of Origin):
DE

Siemens 3LD Series Switch Disconnector, 16A Rated Current, 600V ac Operating Voltage - 3LD2017-0TK13


This switch disconnector provides a manual emergency-off isolator for three-pole circuits in industrial installations. It is intended for floor mounting with door coupling and a defeatable knob-operated mechanism featuring a red/yellow handle. The device supports main-switch use and maintenance isolation while offering IP65 front protection for use in varied indoor and sheltered outdoor settings.

Features and Benefits:


• 16A rated current for sustained circuit switching
• 8kW switching power at AC-23 for motor and load control
• IP65 front protection for ingress resistance
• Padlock compatible to secure the OFF position
• Operating range -25°C to 55°C for broad ambient use

Applications


• Suitable for machinery emergency-off isolation on factory floors
• Ideal for integration with control panels having door coupling
• Used with motor loads requiring AC-23 switching capability
• Can be used where padlockable safety isolation is required
• Suitable for installations demanding IP65-rated controls

What types of connections does it accept?


The main circuit uses box terminals for copper conductors up to 6mm² solid or stranded, with auxiliary connection terminals for auxiliary switches.

How is short-circuit protection managed?


The main circuit requires a gL/gG fuse and is specified with upstream fuse ratings and let-through current limits for coordinated protection.

What auxiliary contact options are available?


Up to three NC and five NO attachable auxiliary contacts can be fitted, with the auxiliary switch rated for 10A continuous current.

What approvals cover electrical and safety ratings?


It meets UL 60947-4-1 and UL 508 requirements for operational current and voltage at 50/60Hz, including specified SCCR values at 600V.

How is the device mounted and secured mechanically?


It is a fixed-mounting device with four-hole front mounting and supports rail mounting

the handle uses a four-hole mounting configuration for fastening.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。