Fluke 1587FC/TPAK/C25 Insulation Multimeter, 50 V Min, 1000 V Max, 2 GΩ CAT III 1000 V, CAT IV 600 V
- RS庫存編號:
- 458-113
- 製造零件編號:
- FLK-1587FC/TPAK/C25
- 製造商:
- Fluke
小計(1 件)*
TWD36,339.00
(不含稅)
TWD38,155.95
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 17 件從 2026年3月23日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD36,339.00 |
* 參考價格
- RS庫存編號:
- 458-113
- 製造零件編號:
- FLK-1587FC/TPAK/C25
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Model Number | 1587FC/TPAK/C25 | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Multimeter | |
| Maximum Test Voltage | 1000V | |
| Minimum Test Voltage | 50V | |
| Display Type | Backlight | |
| Test Current | 1mA | |
| Power Source | Battery | |
| Battery Life | 1000h | |
| Battery Type | AA | |
| Insulation Testing Resistance | 2GΩ | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Safety Category Voltage | 1000V | |
| Safety Category Level | CAT III 1000 V, CAT IV 600 V | |
| Standards/Approvals | IEC 610102033, IEC 610101, IEC 60529: IP40, IEC 6132622, IEC 613261, CISPR 11 | |
| Height | 5cm | |
| Length | 2030000.00mm | |
| Weight | 550g | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Model Number 1587FC/TPAK/C25 | ||
Product Type Insulation Tester | ||
Tester Type Insulation Multimeter | ||
Maximum Test Voltage 1000V | ||
Minimum Test Voltage 50V | ||
Display Type Backlight | ||
Test Current 1mA | ||
Power Source Battery | ||
Battery Life 1000h | ||
Battery Type AA | ||
Insulation Testing Resistance 2GΩ | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Safety Category Voltage 1000V | ||
Safety Category Level CAT III 1000 V, CAT IV 600 V | ||
Standards/Approvals IEC 610102033, IEC 610101, IEC 60529: IP40, IEC 6132622, IEC 613261, CISPR 11 | ||
Height 5cm | ||
Length 2030000.00mm | ||
Weight 550g | ||
- COO (Country of Origin):
- US
Fluke Insulation Tester, 1000V Maximum Test Voltage, 2GΩ Insulation Testing Resistance - FLK-1587FC/TPAK/C25
This insulation tester is a handheld, battery-powered instrument that combines insulation resistance measurement with multimeter functions for field diagnostics and preventive maintenance in industrial environments. It is designed for use on live and de-energised equipment, providing insulation resistance up to very high values and selectable test voltages to assess insulation condition under controlled test currents. The unit is suited to technicians working on motors, drives and electrical systems where portable, rugged measurement capability is required.
Features & Benefits
• Insulation range to 2GΩ for detecting high-resistance faults
• Test voltages selectable up to 1000V for versatile inspections
• Nominal test current 1mA to exercise insulation without overload
• Live-circuit inhibit prevents testing if greater than 30V present for safety
• Backlit 6000-count display for clear readings in low light
• Operates on AA batteries delivering around 1000 h of meter use
• Test voltages selectable up to 1000V for versatile inspections
• Nominal test current 1mA to exercise insulation without overload
• Live-circuit inhibit prevents testing if greater than 30V present for safety
• Backlit 6000-count display for clear readings in low light
• Operates on AA batteries delivering around 1000 h of meter use
Applications
• Suitable for motor winding insulation assessment with VFDs
• Ideal for commissioning and preventive maintenance checks
• Used for troubleshooting insulation degradation on switchgear
• Can be used for asset baseline recording in industrial plants
• Suitable for on-site field testing of cables and installations
• Ideal for commissioning and preventive maintenance checks
• Used for troubleshooting insulation degradation on switchgear
• Can be used for asset baseline recording in industrial plants
• Suitable for on-site field testing of cables and installations
How does the instrument handle capacitive loads during insulation tests?
It is operable with capacitive loads up to 1 μF and auto-discharges capacitive voltage rapidly, with discharge time less than 0.5 s for C = 1 μF or less.
What environmental limits apply for onsite use?
The unit functions between -20 °C and 55 °C and can be stored between -40 °C and 60 °C
humidity limits vary with temperature up to 95% non‑condensing at 10 °C–30 °C.
What protection and safety categories does it meet?
It is rated for CAT III 1000V and CAT IV 600V measurement categories and meets IEC safety standards including IEC 61010 variants.
How is data handling supported for trend analysis and storage?
When used with compatible wireless tools and software it enables timed ratio tests, trend graphs, memory storage and temperature compensation via a measurements app.
What accessory options improve field usability?
Accessories include remote probe, test leads, crocodile clips, a magnetic hanger option and a soft case for site work.
相關連結
- Fluke 179/TPAK/C25 Digital Multimeter CAT IV 600 V
- Fluke 1577 Insulation Tester 1000 V Max CAT IV
- Fluke 1507 Insulation Tester 1000 V Max CAT IV
- Extech MG320 Insulation Tester 1000 V Max, 20 GΩ CAT IV
- Extech MG310 Insulation Tester 1000 V Max, 5.5 GΩ CAT III
- RS PRO IIT1500 Insulation Tester 1000 V Max, 200 GΩ CAT IV
- Megger MIT420 2 Insulation Tester 1000 V Max, 200 GΩ CAT IV
- Megger MIT410 2 Insulation Tester 1000 V Max, 200 GΩ CAT IV