Alpha Wire Hookup Wire PVC Series Green, Yellow 0.75 mm² Hook Up Wire, 18 AWG, 16 x 0.25 mm, 250 μm core strands, 30 m,
- RS庫存編號:
- 842-5466
- Distrelec 貨號:
- 300-83-119
- 製造零件編號:
- 3075 GY005
- 製造商:
- Alpha Wire
可享批量折扣
查看批量定價選項小計(1 卷,共 30 米)*
TWD3,900.00
(不含稅)
TWD4,095.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 34 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷 | 每卷 | 每米* |
|---|---|---|
| 1 - 24 | TWD3,900.00 | TWD130.00 |
| 25 - 49 | TWD3,714.00 | TWD123.80 |
| 50 + | TWD3,588.00 | TWD119.60 |
* 參考價格
- RS庫存編號:
- 842-5466
- Distrelec 貨號:
- 300-83-119
- 製造零件編號:
- 3075 GY005
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Cross Sectional Area | 0.75mm² | |
| Product Type | Hook Up Wire | |
| Jacket Colour | Green, Yellow | |
| American Wire Gauge | 18AWG | |
| Core Strands | 16 x 250 μm | |
| Cable Length | 30m | |
| Outside Diameter | 2.82mm | |
| Voltage | 600V | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Tinned Copper | |
| Sub Type | 3075 Hookup Wire | |
| Cable Type | Single Core | |
| Jacket Material | Polyvinyl Chloride | |
| Standards/Approvals | AWM I A/B, AWM/STYLE 1231, CE:EU Low Voltage Directive 2006/95/EC, CSA International TEW-106, FT2, MTW, UL AWM/STYLE 1016, VW-2 | |
| Minimum Operating Temperature | -40°C | |
| Fire Behaviour | Flame Retardant | |
| Series | Hookup Wire PVC | |
| Number of Strands | 16 | |
| Size of Strands | 250μm | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Cross Sectional Area 0.75mm² | ||
Product Type Hook Up Wire | ||
Jacket Colour Green, Yellow | ||
American Wire Gauge 18AWG | ||
Core Strands 16 x 250 μm | ||
Cable Length 30m | ||
Outside Diameter 2.82mm | ||
Voltage 600V | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Tinned Copper | ||
Sub Type 3075 Hookup Wire | ||
Cable Type Single Core | ||
Jacket Material Polyvinyl Chloride | ||
Standards/Approvals AWM I A/B, AWM/STYLE 1231, CE:EU Low Voltage Directive 2006/95/EC, CSA International TEW-106, FT2, MTW, UL AWM/STYLE 1016, VW-2 | ||
Minimum Operating Temperature -40°C | ||
Fire Behaviour Flame Retardant | ||
Series Hookup Wire PVC | ||
Number of Strands 16 | ||
Size of Strands 250μm | ||
- COO (Country of Origin):
- MX
Belden Hookup Wire PVC Series Hook Up Wire, 0.75mm² Cross Sectional Area, Green/Yellow Jacket - 3075 GY001
This hook-up wire is a flexible insulated conductor intended for signal and control wiring in industrial and vehicle installations. It combines a multi-strand copper core with a PVC outer sheath to deliver dependable electrical connection at elevated temperatures and in constrained routing environments typical of automation, electronics and electrical assemblies.
Features & Benefits
• 0.75mm² conductor minimises voltage drop for Compact circuits
• 16-strand copper core improves flexibility for tight bends
• Rated to 105°C for elevated-temperature operation
• 600V insulation supports medium-voltage control systems
• LSZH and flame-retardant materials reduce smoke and halogen emissions
• Complies with multiple safety standards for regulatory acceptance
• 16-strand copper core improves flexibility for tight bends
• Rated to 105°C for elevated-temperature operation
• 600V insulation supports medium-voltage control systems
• LSZH and flame-retardant materials reduce smoke and halogen emissions
• Complies with multiple safety standards for regulatory acceptance
**Applications**
• Suitable for wiring control panels and Terminal blocks in machinery
• Ideal for automotive harness repairs and auxiliary circuits
• Used for internal wiring of industrial equipment and instruments
• Can be used for cabinet interconnects requiring flame retardance
• Ideal for automotive harness repairs and auxiliary circuits
• Used for internal wiring of industrial equipment and instruments
• Can be used for cabinet interconnects requiring flame retardance
What conductor construction aids repeated flexing during installation?
The conductor is MADE from numerous fine copper strands which provide enhanced pliability and resistance to fatigue under multiple bend cycles.
How should the cable be routed to avoid mechanical stress?
Maintain a minimum bend radius of 5x the cable diameter and avoid Sharp edges to prevent insulation damage and conductor strain.
What labelling or colour options are available to assist identification?
The sheath is offered in green/yellow for protective earth identification as well as solid green and yellow variants for phase or signal coding.
How is environmental safety addressed in material selection?
Materials meet RoHS restrictions and have low levels of substances of very high concern, reducing hazardous substance content in end products.
Standards
UL AWM 1015, 1028, 1230, 1231, 1232, 1283, 1284, UL MTW (22 to 1/0 AWG), UL THW (6 to 1/0 AWG), CSA AWM I A/B FT1 and TEW 105, UL VW-1
相關連結
- Alpha Wire Hookup Wire PVC Series Red 0.75 mm² Hook Up Wire 16/0.25 mm 30 m, Polyvinyl
- Alpha Wire Hookup Wire PVC Series Blue 0.75 mm² Hook Up Wire 16/0.25 mm 30 m, Polyvinyl
- Alpha Wire Hookup Wire PVC Series Black 0.75 mm² Hook Up Wire 16/0.25 mm 30 m, Polyvinyl
- Alpha Wire Hookup Wire PVC Series Black Hook Up Wire 16/0.25 mm 305 m, Polyvinyl
- Alpha Wire Hookup Wire PVC Series Green 16 AWG 0.25 mm core strands 3077 GY005
- Alpha Wire Hookup Wire PVC Series Blue Hook Up Wire 16/0.25 mm 30 m
- Alpha Wire Hookup Wire PVC Series Green 18 AWG 0.25 mm core strands Polyvinyl
- Alpha Wire Hookup Wire PVC Series Green 22 AWG 0.25 mm core strands Polyvinyl