Alpha Wire Ecogen Ecowire Series Brown 0.75 mm² Hook Up Wire, 18 AWG, 16, 305 m, Modified Polyphenylene Ether, 6715
- RS庫存編號:
- 741-8158
- 製造零件編號:
- 6715 BR001
- 製造商:
- Alpha Wire
可享批量折扣
小計(1 卷,共 305 米)*
TWD14,959.00
(不含稅)
TWD15,706.95
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷 | 每卷 | 每米* |
|---|---|---|
| 1 - 49 | TWD14,959.00 | TWD49.046 |
| 50 + | TWD14,215.00 | TWD46.607 |
* 參考價格
- RS庫存編號:
- 741-8158
- 製造零件編號:
- 6715 BR001
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Product Type | Hook Up Wire | |
| Cross Sectional Area | 0.75mm² | |
| Jacket Colour | Brown | |
| American Wire Gauge | 18AWG | |
| Core Strands | 16 | |
| Cable Length | 305m | |
| Voltage | 600V | |
| Outside Diameter | 0.067in | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Jacket Material | Modified Polyphenylene Ether | |
| Standards/Approvals | CE, CSA, UL | |
| Sub Type | EcoWire | |
| Minimum Operating Temperature | -40°C | |
| Fire Behaviour | Flame Retardant | |
| Series | Ecogen Ecowire | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Product Type Hook Up Wire | ||
Cross Sectional Area 0.75mm² | ||
Jacket Colour Brown | ||
American Wire Gauge 18AWG | ||
Core Strands 16 | ||
Cable Length 305m | ||
Voltage 600V | ||
Outside Diameter 0.067in | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Jacket Material Modified Polyphenylene Ether | ||
Standards/Approvals CE, CSA, UL | ||
Sub Type EcoWire | ||
Minimum Operating Temperature -40°C | ||
Fire Behaviour Flame Retardant | ||
Series Ecogen Ecowire | ||
Belden Ecogen Ecowire Series Hook Up Wire, 0.75mm² Cross Sectional Area, Brown Jacket - 6715 BR001
This hook-up wire is designed for internal wiring and interconnection tasks in electrical and electronic assemblies, offering a balance of flexibility and thermal endurance for demanding installations. It is a brown insulated conductor suitable for routine signal and power distribution within control panels, enclosures and apparatus where a 600V rating and elevated temperature capability are required.
Features & Benefits
• 0.75mm² cross section provides reliable current capacity and handling
• 16 copper strands deliver enhanced flexibility for routing
• Rated 600Vrms for standard control and power circuits
• Maximum operating temperature 105°C for high-heat environments
• Flame-performance meeting IEC60332-2 improves circuit safety
• Modified polyphenylene ether insulation offers chemical resistance
• 16 copper strands deliver enhanced flexibility for routing
• Rated 600Vrms for standard control and power circuits
• Maximum operating temperature 105°C for high-heat environments
• Flame-performance meeting IEC60332-2 improves circuit safety
• Modified polyphenylene ether insulation offers chemical resistance
**Applications**
• Suitable for internal wiring of control panels and switchgear
• Ideal for instrumentation and sensor cable assemblies
• Used for interconnection in automation cabinets
• Can be used for appliance internal leads requiring elevated temperature rating
• Suitable for wiring in electrical assemblies requiring brown identification
• Ideal for instrumentation and sensor cable assemblies
• Used for interconnection in automation cabinets
• Can be used for appliance internal leads requiring elevated temperature rating
• Suitable for wiring in electrical assemblies requiring brown identification
What conductor construction aids pliability during installation?
The conductor comprises multiple fine copper strands which reduce stiffness and ease bending in confined routes.
How does the insulation support electrical safety in Compact installations?
The modified polyphenylene ether sheath maintains dielectric properties while resisting many common chemicals and thermal stress.
Which flame and vertical burn behaviours are provided for risk mitigation?
It meets VW-1 and IEC60332-2 vertical flame test criteria and FT1 classification for single-wire flame behaviour.
What approvals indicate suitability for global manufacturing environments?
It conforms to standards including UL AWM STYLE11028, CSA AWM I A/B FT1, and CE LVD requirements, and meets RoHS and REACH substance restrictions.
Standards
UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant
相關連結
- Alpha Wire Ecogen Ecowire Series Green 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether, 6715
- Alpha Wire Ecogen Ecowire Series White 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether, 6715
- Alpha Wire Ecogen Ecowire Series Yellow 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether, 6715
- Alpha Wire Ecogen Ecowire Series Black 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether, 6715
- Alpha Wire Ecogen Ecowire Series Purple 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether, 6715
- Alpha Wire Ecogen Ecowire Series Dark Blue Hook Up Wire 16 Modified Polyphenylene Ether, 6715 DB001
- Alpha Wire Ecogen Ecowire Series Dark Blue Hook Up Wire 16 Modified Polyphenylene Ether, 6715 DB005
- Alpha Wire Ecogen Ecowire Series Red 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether, 6715 RD005
