Eaton 125A Fuse Holder for 22 x 58 mm, 2P-Pole, 690V

小計(1 包,共 3 件)*

TWD12,962.00

(不含稅)

TWD13,610.10

(含稅)

Add to Basket
選擇或輸入數量
庫存資訊目前無法存取 - 請稍後再回來查看
每包
每單位*
1 +TWD12,962.00TWD4,320.667

* 參考價格

RS庫存編號:
228-789
製造零件編號:
CH222DIU 2P 22x58 Neon Indicator Fuse Holder
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Product Type

Fuse Holder

Current Rating

125A

Voltage

690V

Number of Poles

2

Rail Type

DIN Rail

Case Material

Polyester

Indicator

Yes

Minimum Operating Temperature

-20°C

Compatible Fuse Size

22 x 58 mm

Maximum Operating Temperature

70°C

Standards/Approvals

IEC 60269-2, IEC 60269-1, RoHS, CE, UL, EAC

Series

Eaton's Bussmann

豁免

COO (Country of Origin):
CN

Eaton Fuse Holder, 125A Current Rating, 22x58mm Compatible Fuse size - CH222DIU 2P 22x58 Neon Indicator Fuse Holder


This fuse holder provides a DIN-rail mounted solution for housing 22x58 fuses with an integrated neon status indicator. It is intended for use in industrial electrical and automation panels where controlled disconnection and visible fuse condition are required. The unit accommodates two poles and is designed for installations operating at elevated voltages and currents within typical industrial systems.

Features & Benefits


• Polyester enclosure offering electrical insulation and thermal stability
• Rated for continuous 125A service enabling high-current protection
• Two-pole configuration for combined circuit protection and isolation
• Suitable for up to 690V allowing use in three-phase infrastructure
• JV-L multipole Terminal for secure multi-conductor connections
• Conforms to IEC60269 standards for consistent fuse coordination

Applications


• Suitable for distribution panels in factory automation systems
• Ideal for protecting motor control circuits in mechanical plants
• Used with power assemblies in electrical distribution switchboards
• Can be used for high-current protection in industrial control cabinets

What temperature range can it reliably operate within?


It is specified to function between -20°C and 70°C, covering typical indoor industrial ambient conditions.

How is the unit mounted within control enclosures?


It is designed for DIN-rail mounting to integrate with standard panel racking and facilitate organised wiring.

Which Terminal Interface is used for conductor connections?


It employs a JV-L multipole connector arrangement to accept multiple conductors per pole and support secure electrical contact.

What standards guide its fuse compatibility and safety aspects?


The design aligns with IEC60269-1 and IEC60269-2 requirements and carries recognised safety approvals for industrial use.

相關連結