Eaton 160A Fuse Holder, 3P-Pole for NH000/NH00 Fuse

小計(1 件)*

TWD18,382.00

(不含稅)

TWD19,301.10

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年7月22日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD18,382.00

* 參考價格

RS庫存編號:
127-227
製造零件編號:
183041 XNH00-FCE-S160-BT2
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Product Type

Fuse Holder

Current Rating

160A

Number of Poles

3

Body Material

Polyamide

IP Rating

IP10, IP20, IP2XC

Minimum Operating Temperature

-5°C

Compatible Fuse Size

NH000/NH00 Fuse

Maximum Operating Temperature

55°C

Standards/Approvals

IEC/EN 61439, RoHS

Series

xEffect

Terminal Type

Clamp

COO (Country of Origin):
DE

Eaton xEffect Series Fuse Holder, 160A Current, 800V Voltage - 183041 XNH00-FCE-S160-BT2


This fuse holder is a three-pole NH00 device designed for busbar systems and front mounting, providing a selectable protective element Interface for low-voltage switchgear and distribution panels. It incorporates electronic fuse monitoring with Visual indicators and allows cable connection at TOP or bottom to suit different installation arrangements.

Features & Benefits


• Rated operational current 160A for continuous operation
• Rated insulation voltage 800V for high-voltage environments
• Conditioned short-circuit capability 120 kA to withstand faults
• Electronic fuse monitoring with LEDs and test function for diagnostics
• Box Terminal accommodating 1.5mm² to 95mm² for flexible wiring
• Mounts to 60mm busbars for straightforward panel integration

Applications


• Suitable for industrial distribution boards using NH00 fuses
• Used for switchgear assemblies requiring electronic fuse surveillance
• Ideal for retrofit busbar systems needing front-access fuse carriers
• Suitable for control panels in automation and manufacturing plants

What indicators are provided for fuse status and diagnostics?


Three red LEDs indicate individual fuse faults, one green LED shows system status, and a test button exercises the relay and LEDs.

How does the device connect to busbars and conductors?


Main circuit connection uses frame clamps for copper busbars with M8 flange bolts and supports 20mm x 10mm busbar strips and up to 25mm cable lug width.

What environmental limits apply to operation and storage?


The operational ambient range is -25 °C to 55 °C, with recommended continuous operation between -5 °C and 55 °C and a maximum operating temperature of 70 °C for component limits.

Which mechanical and electrical lifespans can be expected?


Mechanical endurance is rated at 1,400 operations and electrical switching life at 300 operations under specified conditions.

Are there any built-in safety or material characteristics relevant to panel design?


The enclosure is halogen-free, self-extinguishing (UL94), and provides IP20 protection in installed, operating status with additional contact-protection ratings of IP3X and IP2XC.