Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid, 0.1L/min Min, 75L/min Max
- RS庫存編號:
- 256-6153
- Distrelec 貨號:
- 303-51-192
- 製造零件編號:
- DMA20-AAABA1
- 製造商:
- Endress+Hauser
小計(1 件)*
TWD22,849.00
(不含稅)
TWD23,991.45
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 16 件從 2026年10月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD22,849.00 |
* 參考價格
- RS庫存編號:
- 256-6153
- Distrelec 貨號:
- 303-51-192
- 製造零件編號:
- DMA20-AAABA1
- 製造商:
- Endress+Hauser
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Endress+Hauser | |
| Media Monitored | Liquid | |
| Product Type | Flow Meter | |
| Device Type | Electromagnetic Flowmeter | |
| Minimum Flow Rate | 0.1L/min | |
| Maximum Flow Rate | 75L/min | |
| Housing Material | 316L Stainless Steel | |
| Connection Type | Thread | |
| Maximum Pressure | 16bar | |
| IP Rating | IP65, IP67 | |
| Minimum Media Temperature | -10°C | |
| Maximum Supply Voltage | 30V dc | |
| Minimum Operating Temperature | -10°C | |
| Maximum Media Temperature | 70°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | CE mark | |
| Series | DMA20 | |
| 選取全部 | ||
|---|---|---|
品牌 Endress+Hauser | ||
Media Monitored Liquid | ||
Product Type Flow Meter | ||
Device Type Electromagnetic Flowmeter | ||
Minimum Flow Rate 0.1L/min | ||
Maximum Flow Rate 75L/min | ||
Housing Material 316L Stainless Steel | ||
Connection Type Thread | ||
Maximum Pressure 16bar | ||
IP Rating IP65, IP67 | ||
Minimum Media Temperature -10°C | ||
Maximum Supply Voltage 30V dc | ||
Minimum Operating Temperature -10°C | ||
Maximum Media Temperature 70°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals CE mark | ||
Series DMA20 | ||
- COO (Country of Origin):
- FR
Endress+Hauser DMA20 Series Flow Meter, 0.1 L/min Minimum Flow Rate, 16 Bar Maximum Pressure - DMA20-AAABA1
This flow metre is an electromagnetic instrument designed to measure liquid flow in inline, threaded installations. It performs metering duties across a wide flow range and is intended for industrial environments where robust construction and electrical compatibility are required.
Features and Benefits:
• 0.1-75 L/min range allows precise low-to-medium flow measurement
• Withstands up to 16 bar enabling use under moderate pressure
• Operates between -10°C and 70°C handling varying media temperatures
• 316L stainless steel housing resists corrosive process fluids
• IP65 and IP67 ingress protection supports wet and washdown areas
• Accepts up to 30V DC supply for common control systems
• Withstands up to 16 bar enabling use under moderate pressure
• Operates between -10°C and 70°C handling varying media temperatures
• 316L stainless steel housing resists corrosive process fluids
• IP65 and IP67 ingress protection supports wet and washdown areas
• Accepts up to 30V DC supply for common control systems
Applications
• Suitable for municipal water distribution monitoring
• Ideal for chemical dosing and metering lines
• Used with process control cabinets in food processing plants
• Can be used for cooling circuit flow measurement in manufacturing
• Suitable for utility skid installations requiring threaded connections
• Ideal for chemical dosing and metering lines
• Used with process control cabinets in food processing plants
• Can be used for cooling circuit flow measurement in manufacturing
• Suitable for utility skid installations requiring threaded connections
What connection type does it provide for inline mounting?
It uses a threaded connection intended for direct inline coupling to pipework fittings.
What media can be measured with this instrument?
It is intended for liquid media compatible with stainless-steel wetted parts and the specified temperature limits.
How does it cope with washdown and temporary immersion?
The enclosure meets both IP65 and IP67 ratings, offering protection against jets of water and brief submersion.
What electrical supply constraints must be observed?
The device must not be driven above the maximum 30V DC supply rating.
What operational temperature limits apply to ambient and process conditions?
The instrument accepts media and ambient operation down to -10°C and up to 60°C for ambient, with media contact temperature permitted to 70°C.
相關連結
- Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid 75L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 75L/min Max
- Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid 150L/min Max
- Endress+Hauser DMA50 Series Electromagnetic Flowmeter Flow Meter for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 150L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 35L/min Max
- Key Instruments FR5000 Series Variable Area Flow Meter for Liquid 75L/min Max