Figaro TGS822-A00 Organic Vapour Air Quality Sensor for Solvent Detectors for Factories, Semiconductor, Dry Cleaner,

可享批量折扣

小計(1 件)*

TWD840.00

(不含稅)

TWD882.00

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 9 件從 2026年3月09日 起裝運發貨
  • 加上 30 件從 2026年3月13日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 - 1TWD840.00
2 +TWD815.00

* 參考價格

RS庫存編號:
134-6673
製造零件編號:
TGS822-A00
製造商:
Figaro
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Figaro

Gases Detected

Organic Vapour

Product Type

Air Quality Sensor

Application

Solvent Detectors for Factories, Semiconductor, Dry Cleaner, Breath Alcohol Detector, Gas Leak Detectors & Alarm

Sub Type

Gas Sensor

Minimum Supply Voltage

0.2V

Maximum Supply Voltage

24V

Power Source

AC or DC Power Supply

Pin Count

6

Minimum Operating Temperature

-20°C

Package Type

Module

Maximum Operating Temperature

50°C

Standards/Approvals

No

Series

TGS 822

Length

16.5mm

Width

9.5 mm

Automotive Standard

No

TGS821, TGS822, TGS823 & TG826 Gas Sensors


A range of gas sensors from Figaro utilising tin dioxide (SnO2) semiconductor technology. In clean air the devices have low conductivity which increases in the presence of a detectable gas. A simple electrical circuit can be used to convert the change in conductivity to an output signal proportional to gas concentration.

• Type TGS821 has high sensitivity and selectivity to hydrogen gas. The sensor can detect concentrations as low as 50ppm, making it ideal for a variety of industrial applications.

• Types TGS822 & TGS823 have high sensitivity to the vapours of organic solvents and a variety of combustible gases such as carbon monoxide, making them good general purpose sensors; type TGS823 has a ceramic base able to withstand temperatures of up to 200°C.

• Type TGS826 has high sensitivity to ammonia gas and can detect concentrations as low as 30ppm. It is ideally suited to critical safety-related applications such as the detection of ammonia leaks in refrigeration systems and ammonia detection in the agricultural field.

PCB Mounted Gas Sensors


Operating conditions in which Sensors are used will vary with each customer's application. Gas and oxygen sensors are not authorised for use as critical components in life support applications wherein a failure or malfunction of the products may result in injury or threat to life. Non-calibrated PCB gas sensors will not operate properly if not calibrated prior to usage.

Semiconductor gas sensors for gas detection, air quality control, HVAC, appliance and automotive industries. Characteristics of the products in this range are small size, low cost, long life, low power consumption and no maintenance requirement