MEAN WELL RSD 150 DC/DC Converter, 5V dc/, 24V dc Input 30 A, 16.8V Input, Chassis, 70 °C Max Temp -40 °C Min Temp

此圖片僅供參考,請參閲產品詳細資訊及規格

可享批量折扣
查看批量定價選項

小計(1 件)*

TWD3,198.00

(不含稅)

TWD3,357.90

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 6 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。

單位
每單位
1 - 4TWD3,198.00
5 - 9TWD3,135.00
10 - 24TWD3,041.00
25 - 49TWD2,950.00
50 +TWD2,891.00

* 參考價格

RS庫存編號:
753-7833
Distrelec 貨號:
301-56-951
製造零件編號:
RSD-150B-5
製造商:
MEAN WELL
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

MEAN WELL

Output Voltage 1

5V dc

Product Type

DC/DC Converter

Maximum Input Voltage

24V dc

Minimum Input Voltage

16.8V

Output Current 1

30A

Output Current 2

30A

Mount Type

Chassis

MTBF

223200h

Number of Outputs

1

Ripple and Noise

100mV Pk-Pk

Isolation Voltage

4kV dc

Input Ratio

2:1

Maximum Output Power

150W

Length

189mm

Depth

36mm

Weight

800g

Standards/Approvals

EN/IEC

Series

RSD 150

Width

36mm

Efficiency

89%

Maximum Operating Temperature

70°C

Minimum Operating Temperature

-40°C

Mean Well 150W Railway Certified Regulated Isolated DC-DC Converter - RSD 150 Series


150W enclosed single output isolated DC to DC converters with a 2:1 wide input range and a 1U low profile of 36mm. The design of these single output isolated DC to DC converters complies with railway certificates (EN50155, IEC60571, IEC61373, EN50121-3-2) making them suitable for use in vehicles that are equipped with DC power source. These railway certified isolated DC to DC converters have a high efficiency circuit design and are semi-encapsulated for PCB protection.

2:1 wide input range

Up to 92% efficiency

4000VDC I/O isolation

Compliance to EN50155 (railway certification)

Free air convection cooling

Semi-encapsulated for PCB protection

Built-in constant current limiting circuit

Use of 105°C long life electrolytic capacitors

100% full load burn-in test

5G anti-vibration ability

LED indication for power-on

Short circuit, overload, over voltage, over temperature and input reverse polarity protection

EMC compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B ; EN50121-3-2

Note

MTBF to MIL-HDBK-217F (25°C )
Power derates above 55°C (without base plate), no derating with base plate

Standards

Meet IEC60950-1(LVD)
Railway standards: Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC