TRACOPOWER TEN 30 DC/DC Converter, 5.1V/ 6 A, 36V dc Input, 18V Input 30 W, PCB, 85 °C Max Temp -40 °C Min Temp, 6-Pin

此圖片僅供參考,請參閲產品詳細資訊及規格

可享批量折扣

小計(1 件)*

TWD1,908.00

(不含稅)

TWD2,003.40

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 12 件準備從其他地點送貨
  • 加上 1 件從 2026年5月11日 起發貨
  • 加上 10 件從 2026年5月21日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。

單位
每單位
1 - 2TWD1,908.00
3 - 4TWD1,870.00
5 +TWD1,832.00

* 參考價格

RS庫存編號:
666-4310
Distrelec 貨號:
300-80-753
製造零件編號:
TEN 30-2411
製造商:
TRACOPOWER
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

TRACOPOWER

Product Type

DC/DC Converter

Output Voltage 1

5.1V

Maximum Input Voltage

36V dc

Minimum Input Voltage

18V

Output Current 1

6A

Output Current 2

6A

Mount Type

PCB

Input Ratio

2:1

Number of Outputs

1

MTBF

1400000h

Output Voltage Adjustment Range

±10 %

Isolation Voltage

1.5kV dc

Number of Pins

6

Package Type

Encapsulated

Maximum Output Power

30W

Depth

10.2mm

Standards/Approvals

No

Width

50.8mm

Length

25.4mm

Series

TEN 30

Maximum Operating Temperature

85°C

Minimum Operating Temperature

-40°C

Efficiency

90%

Traco 30W Single/Dual Output High Power Density Regulated Isolated DC-DC Converter - TEN 30 Series


30W single/dual output high power density regulated isolated DC-DC converter modules with a wide input voltage range and encapsulated metal package. These single/dual output high power density regulated isolated DC-DC converter modules have a high efficiency which allows an operating temperature range of -40°C to +85°C. Typical applications for these isolated DC-DC converter modules include mobile equipment, instrumentation and distributed power architectures in communication and industrial electronics.

High power density, 25.4x50.8x10.2mm package

Wide 2:1 input voltage range

Regulated outputs

±10% adjustable output voltage by using external resistors (single output models only)

1.5kV input / output isolation

High efficiency up to 91%

No minimum load required

Input filter meets EN 55022 Class A

Remote On/Off

Over-temperature, over-voltage, over-load and short circuit protection

Shielded metal case with insulated baseplate

Industry standard pin-out

Note

Operating temperature is with derating of 4% per °C above 65°C.
MTBF to MIL-HDBK-217F (25°C).
Load regulation for dual output models is for balanced load.
For suitable heatsink see stock number 745-1234
For suitable common mode chokes see stock number 745-1222 (L1) and 745-1231 (L2)

Standards

EN 60950-1, UL 60950-1, IEC 60950-1

相關連結