Fluke 715 Current & Voltage Calibrator, Max Voltage 20V 20 mA
- RS庫存編號:
- 263-2700
- Distrelec 貨號:
- 176-78-006
- 製造零件編號:
- FLUKE 715
- 製造商:
- Fluke
小計(1 件)*
TWD69,165.00
(不含稅)
TWD72,623.25
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 11 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD69,165.00 |
* 參考價格
- RS庫存編號:
- 263-2700
- Distrelec 貨號:
- 176-78-006
- 製造零件編號:
- FLUKE 715
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Current & Voltage Calibrator | |
| Maximum Voltage Measurement | 20V | |
| Maximum Current Measurement | 20mA | |
| Accuracy | ± 0.01 % | |
| Standards/Approvals | CSA C22.2 No. 1010.1:1992 | |
| Power Source | Battery | |
| Battery Type | Alkaline | |
| Weight | 330g | |
| Height | 201mm | |
| Length | 187mm | |
| Maximum Operating Temperature | 55°C | |
| Hazardous Area Certification | No | |
| Maximum Source Current | 24mA | |
| Model Number | 715 | |
| Minimum Operating Temperature | -10°C | |
| Minimum Source Current | 4mA | |
| Minimum Source Voltage | 100mV | |
| Maximum Source Voltage | 10V | |
| Width | 87mm | |
| Safety Category Voltage | 30V | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Current & Voltage Calibrator | ||
Maximum Voltage Measurement 20V | ||
Maximum Current Measurement 20mA | ||
Accuracy ± 0.01 % | ||
Standards/Approvals CSA C22.2 No. 1010.1:1992 | ||
Power Source Battery | ||
Battery Type Alkaline | ||
Weight 330g | ||
Height 201mm | ||
Length 187mm | ||
Maximum Operating Temperature 55°C | ||
Hazardous Area Certification No | ||
Maximum Source Current 24mA | ||
Model Number 715 | ||
Minimum Operating Temperature -10°C | ||
Minimum Source Current 4mA | ||
Minimum Source Voltage 100mV | ||
Maximum Source Voltage 10V | ||
Width 87mm | ||
Safety Category Voltage 30V | ||
豁免
Fluke Current & Voltage Calibrator, 24mA Maximum Source Current, 10V Maximum Source Voltage - FLUKE 715
This current & voltage calibrator is a compact, battery-powered tool for calibrating and troubleshooting industrial process loops and voltage outputs. It operates across a practical temperature range and is designed for field use where portability, precision and straightforward controls are required.
Features & Benefits
• 0.01% accuracy for precise calibration and verification
• Source and measure 0mA to 20mA or 4mA to 20mA for loop work
• 24mA sourcing capability to simulate over-range conditions
• Voltage sourcing to 10V for transmitter and PLC checks
• Battery operation with removable door for quick replacement
• Safety rating to 30V for safe bench and field checks
• Source and measure 0mA to 20mA or 4mA to 20mA for loop work
• 24mA sourcing capability to simulate over-range conditions
• Voltage sourcing to 10V for transmitter and PLC checks
• Battery operation with removable door for quick replacement
• Safety rating to 30V for safe bench and field checks
**Applications**
• Suitable for commissioning 4mA to 20mA control loops
• Ideal for maintenance of transmitters and PLC outputs
• Used for field verification of loop-powered instruments
• Can be used for sourcing a 24mA fault condition during tests
• Suitable for portable checks where 0.01% accuracy is required
• Ideal for maintenance of transmitters and PLC outputs
• Used for field verification of loop-powered instruments
• Can be used for sourcing a 24mA fault condition during tests
• Suitable for portable checks where 0.01% accuracy is required
What power source does it use and how is it replaced?
It runs on alkaline batteries and has a removable battery door for Rapid changes in the field.
What environmental range can it be used in?
It operates between -10°C and 55°C and survives non‑operating extremes to -4°C and 60°C.
How does it support HART or resistor-requiring loops?
It provides a 24V loop supply while measuring current and can accommodate typical loop resistances when sourcing 24mA.
What are its portability characteristics for site work?
The instrument is lightweight at 330g and housed in a rugged case suitable for handheld use.
Note
Fitting replacement fuse: RS 323-6965
相關連結
- Time Electronics 1044 Current & Voltage Calibrator, Max Voltage 20V 20 mA
- Extech PRC10 Current & Voltage Calibrator, Max Voltage 20V 24 mA
- Extech 412355A Current & Voltage Calibrator, Max Voltage 20V 24 mA
- Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V dc 24 mA
- Fluke Fluke-712B AR Temperature Calibrator
- Fluke 705 Loop Calibrator Battery 30V
- Fluke 707 Loop Calibrator Battery 30V
- Fluke 709 Loop Calibrator Battery