Alpha Wire Alpha Essentials Communication & Control Control Cable, 9 Cores, 0.56mm² 20 AWG, Unscreened, 30 m, Slate
- RS庫存編號:
- 828-2339
- 製造零件編號:
- 1896/9C SL005
- 製造商:
- Alpha Wire
小計(1 卷,共 30 米)*
TWD7,780.00
(不含稅)
TWD8,169.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 4 件從 2026年5月11日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷 | 每卷 | 每米* |
|---|---|---|
| 1 + | TWD7,780.00 | TWD259.333 |
* 參考價格
- RS庫存編號:
- 828-2339
- 製造零件編號:
- 1896/9C SL005
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Product Type | Control Cable | |
| Series | Alpha Essentials Communication & Control | |
| Number of Cores | 9 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Slate | |
| Screened/Unscreened | Unscreened | |
| Cable Length | 30m | |
| Outside Diameter | 7.65mm | |
| Voltage | 300V | |
| Minimum Operating Temperature | -20°C | |
| Standards/Approvals | UL, CSA, CE | |
| Maximum Operating Temperature | 80°C | |
| Hazardous Area Certification | No | |
| Cable CSA | 0.56mm² | |
| American Wire Gauge | 20AWG | |
| Core Strands | 7 | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Product Type Control Cable | ||
Series Alpha Essentials Communication & Control | ||
Number of Cores 9 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Slate | ||
Screened/Unscreened Unscreened | ||
Cable Length 30m | ||
Outside Diameter 7.65mm | ||
Voltage 300V | ||
Minimum Operating Temperature -20°C | ||
Standards/Approvals UL, CSA, CE | ||
Maximum Operating Temperature 80°C | ||
Hazardous Area Certification No | ||
Cable CSA 0.56mm² | ||
American Wire Gauge 20AWG | ||
Core Strands 7 | ||
豁免
Belden Alpha Essentials Communication & Control Series Control Cable, 30m Cable Length, Slate Jacket - 1896/9C SL005
This control cable is a 9-core, unscreened multiconductor cable intended for control and signalling in industrial environments. It combines stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket, delivering a practical solution for wiring remote controls, instrumentation and low-voltage circuits where a compact, flexible 9-core run is required.
Features & Benefits
• 300V rating for standard control and signal circuits
• -20°C to +80°C operating range for varied environments
• Stranded tinned copper conductors for enhanced corrosion resistance
• 7-strand core construction to retain flexibility under flexing
• Slate PVC jacket for abrasion and chemical resistance
• Unscreened design for low-noise applications where shielding is unnecessary
• -20°C to +80°C operating range for varied environments
• Stranded tinned copper conductors for enhanced corrosion resistance
• 7-strand core construction to retain flexibility under flexing
• Slate PVC jacket for abrasion and chemical resistance
• Unscreened design for low-noise applications where shielding is unnecessary
**Applications**
• Suitable for control and signal wiring in automation cabinets
• Ideal for remote circuit controls and intercom systems
• Used for audio and low-voltage instrumentation connections
• Can be used for telephones and business machine signalling
• Suitable for tray or conduit routes in electrical installations
• Ideal for remote circuit controls and intercom systems
• Used for audio and low-voltage instrumentation connections
• Can be used for telephones and business machine signalling
• Suitable for tray or conduit routes in electrical installations
What conductor construction does it use and why does that matter?
It uses stranded tinned copper conductors with seven strands per core, which improves flexibility and maintains good electrical contact in assemblies requiring bending.
How is the cable jacket specified for installation conditions?
The outer slate PVC jacket offers mechanical protection and chemical resistance suitable for typical industrial routing and handling.
What voltage and temperature limits govern safe use?
The cable is rated to 300V and is certified to operate within a temperature span from -20°C up to +80°C for most control and signal tasks.
How Compact is the cable for panel entry or conduit?
The cable has an outside diameter of 7.65mm, allowing it to fit into confined conduit and gland entries while carrying nine conductors.
Approvals
UL, CSA
相關連結
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.56mm² 20 AWG 30 m, Grey