Alpha Wire Alpha Essentials Communication & Control Control Cable, 5 Cores 24 AWG, Screened, 30 m, Slate Polyvinyl
- RS庫存編號:
- 187-2046
- 製造零件編號:
- 6329 SL005
- 製造商:
- Alpha Wire
小計(1 卷,共 30 米)*
TWD9,210.00
(不含稅)
TWD9,670.50
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 630 件從 2026年5月11日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 | 每卷* |
|---|---|---|
| 30 + | TWD307.00 | TWD9,210.00 |
* 參考價格
- RS庫存編號:
- 187-2046
- 製造零件編號:
- 6329 SL005
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Series | Alpha Essentials Communication & Control | |
| Product Type | Control Cable | |
| Number of Cores | 5 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Slate | |
| Screened/Unscreened | Screened | |
| Cable Length | 30m | |
| Outside Diameter | 5.61mm | |
| Voltage | 300V | |
| Minimum Operating Temperature | -20°C | |
| Standards/Approvals | UL, CSA, CE | |
| Maximum Operating Temperature | 80°C | |
| Hazardous Area Certification | No | |
| American Wire Gauge | 24AWG | |
| Fire Behaviour | VW-1, FT4 | |
| Core Strands | 7 | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Series Alpha Essentials Communication & Control | ||
Product Type Control Cable | ||
Number of Cores 5 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Slate | ||
Screened/Unscreened Screened | ||
Cable Length 30m | ||
Outside Diameter 5.61mm | ||
Voltage 300V | ||
Minimum Operating Temperature -20°C | ||
Standards/Approvals UL, CSA, CE | ||
Maximum Operating Temperature 80°C | ||
Hazardous Area Certification No | ||
American Wire Gauge 24AWG | ||
Fire Behaviour VW-1, FT4 | ||
Core Strands 7 | ||
Belden Alpha Essentials Communication & Control Series Control Cable, 30m Cable Length, 5 Cores - 6329 SL005
This control cable is a screened, five-core connection designed for industrial control and signal transmission in automation and electrical systems. It combines tinned copper conductors and a PVC outer sheath to deliver consistent performance across typical plant environments, operating between -20°C and 80°C.
Features & Benefits
• 300V rating provides safe low-voltage signal distribution
• Screened construction reduces electromagnetic interference on signals
• Tin copper 7-strand conductors improve flexing longevity
• VW-1 FT4 flame-retardant materials enhance fire performance
• Slate PVC jacket resists abrasion and environmental exposure
• 5-core configuration simplifies multi-signal cabling runs
• Screened construction reduces electromagnetic interference on signals
• Tin copper 7-strand conductors improve flexing longevity
• VW-1 FT4 flame-retardant materials enhance fire performance
• Slate PVC jacket resists abrasion and environmental exposure
• 5-core configuration simplifies multi-signal cabling runs
**Applications**
• Suitable for programmable logic controller signal wiring
• Ideal for factory-floor motor control circuits
• Used with sensor arrays and actuator networks
• Can be used for panel interconnect and Terminal strip feeds
• Suitable for machine tool cabling where screening is required
• Ideal for factory-floor motor control circuits
• Used with sensor arrays and actuator networks
• Can be used for panel interconnect and Terminal strip feeds
• Suitable for machine tool cabling where screening is required
What is the conductor construction and why does it matter for movement?
Each conductor is MADE from tinned copper composed of seven strands to balance conductivity with flexibility, reducing fatigue in repeated flexing applications.
How is the cable shield implemented and what electrical benefit does it provide?
The shield combines aluminium/Mylar tape with a tinned copper braid and a drain wire to provide a continuous earth path and lower shield resistance, improving noise rejection.
What printing and marking can be expected on the outer sheath?
The jacket carries manufacturer identification and cable type markings indicating conductor size, core count, screening and temperature rating for installation traceability.
What mechanical limits should installers observe during routing?
Follow a minimum bend radius of ten times the cable diameter and limit pull tension to the specified maximum to avoid conductor or jacket damage.
相關連結
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.25 mm² 24 AWG 1000 ft, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.25 mm² 24 AWG 500 ft, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable Screened Grey Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Control Cable Screened Grey Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Control Cable Screened Grey Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Control Cable Screened Grey Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Control Cable Screened Grey Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Control Cable Screened Grey Polyvinyl