Better World
Schneider Electric TeSyS D Contactor, 230V ac Coil, 3-Pole, 18 A, 7.5 kW 240V, 3 NO, 690V ac
- RS庫存編號:
- 656-7111
- Distrelec 貨號:
- 304-01-267
- 製造零件編號:
- LC1D18U7
- 製造商:
- Schneider Electric
小計(1 件)*
TWD2,769.00
(不含稅)
TWD2,907.45
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 21 件從 2026年4月27日 起發貨
- 加上 32 件從 2026年5月08日 起發貨
- 加上 16 件從 2026年6月05日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD2,769.00 |
* 參考價格
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 656-7111
- Distrelec 貨號:
- 304-01-267
- 製造零件編號:
- LC1D18U7
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Product Type | Contactor | |
| Coil Voltage | 230V ac | |
| Number of Poles | 3 | |
| Contact Voltage | 690V ac | |
| Contact Current | 18A | |
| Series | TeSyS D | |
| Power Rating | 7.5kW | |
| Function | Motor Control, Resistive Load | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 3 NO | |
| Auxiliary Contact Configuration | 1 NO/1 NC | |
| Number of Auxiliary Contacts | 2 | |
| Terminal Type | Screw | |
| Operational Current Ie | 18A | |
| Minimum Operating Temperature | -40°C | |
| Control Circuit Voltage Uc | 240V | |
| Contactor Application | Motor Control, Resistive Load | |
| Maximum Operating Temperature | 60°C | |
| Depth | 86mm | |
| Length | 77mm | |
| Standards/Approvals | RoHS, UL, CCC, CSA, EAC, IEC | |
| Width | 45mm | |
| Better World Product | Yes | |
| Pole and Throw Configuration | 3 | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Product Type Contactor | ||
Coil Voltage 230V ac | ||
Number of Poles 3 | ||
Contact Voltage 690V ac | ||
Contact Current 18A | ||
Series TeSyS D | ||
Power Rating 7.5kW | ||
Function Motor Control, Resistive Load | ||
Mount Type DIN Rail | ||
Normal State Configuration 3 NO | ||
Auxiliary Contact Configuration 1 NO/1 NC | ||
Number of Auxiliary Contacts 2 | ||
Terminal Type Screw | ||
Operational Current Ie 18A | ||
Minimum Operating Temperature -40°C | ||
Control Circuit Voltage Uc 240V | ||
Contactor Application Motor Control, Resistive Load | ||
Maximum Operating Temperature 60°C | ||
Depth 86mm | ||
Length 77mm | ||
Standards/Approvals RoHS, UL, CCC, CSA, EAC, IEC | ||
Width 45mm | ||
Better World Product Yes | ||
Pole and Throw Configuration 3 | ||
豁免
- COO (Country of Origin):
- FR
Schneider Electric Contactor, 7.5kW Power Rating, 2 Auxiliary Contacts - TeSys D Series - LC1D18U7
Is your electrical switching unreliable in hot conditions? This contactor from Schneider Electric can take the heat. It's capable of 3,600 operating cycles an hour in environments up to +60°C. This means high temperatures won't slow it down. The opening and closing time is between 4 and 22ms, so you can be sure switching is swift. As it handles electrical currents up to 32A, you can depend on this contactor to turn heavy loads on and off in manufacturing and plant applications.
Features & Benefits
• Built-in mirror-type auxiliary contacts to carry out signalling duties
• Screw-clamp terminals securely hold your wires, even with vibration
• Panel and rail mounting options to simplify installation
• Mechanical durability of 15 million cycles for a long service life
Applications
• Machine tools
• Pumps and blowers
• Lifts and hoists
• Conveyors
• Materials handling
Can I join two contactors together?
Yes. You can link two contactors using a mechanical interlock, so it's easy to boost your switching capacity.
What type of motors does this contactor work with?
Categorised for AC-1, AC-4 and AC-3e motors, it works with resistive loads and energy-efficient asynchronous motors.
Schneider Electric LC1D TeSys D Contactors
TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards.
Features and Benefits
• Built-in auxiliary contacts for added switching capability
• Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
• Can be panel mounted with screws or DIN Rail mounted
• Bidirectional peak limiting diode suppressor to protect the coil
• Easily installed accessories
• Flexible control circuit to suit a wide range of applications
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
What accessories are available?
• Auxiliary contact blocks with serrated wiping action
• Front mount dust tight auxiliary contact blocks
• Pneumatic time delay blocks
• Transient voltage surge suppressors
• Interface modules and electronic timers
• Mechanical latching blocks
Is the TeSys D range a double break pole type contactor?
Yes the Tesys D range uses linear translation movement that provides double breaking of the poles.