Schneider Electric TeSyS K Reversing Contactor, 230V ac Coil, 3-Pole, 6 A, 4 kW 230V ac, 3 NO, 690V ac
- RS庫存編號:
- 609-0683
- 製造零件編號:
- LC2K0601P7
- 製造商:
- Schneider Electric
可享批量折扣
小計(1 件)*
TWD3,953.00
(不含稅)
TWD4,150.65
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 6 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 5 | TWD3,953.00 |
| 6 - 11 | TWD3,841.00 |
| 12 + | TWD3,637.00 |
* 參考價格
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 609-0683
- 製造零件編號:
- LC2K0601P7
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Coil Voltage | 230V ac | |
| Product Type | Reversing Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V ac | |
| Contact Current | 6A | |
| Power Rating | 4kW | |
| Series | TeSyS K | |
| Mount Type | Plate, Rail Mount | |
| Function | Motor Control, Resistive Load, Reversing | |
| Normal State Configuration | 3 NO | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NC | |
| Terminal Type | Screw Clamp | |
| Minimum Operating Temperature | -25°C | |
| Control Circuit Voltage Uc | 230V ac | |
| Contactor Application | Motor Control | |
| Operational Current Ie | 6A | |
| Maximum Operating Temperature | 50°C | |
| Depth | 57mm | |
| Width | 90mm | |
| Standards/Approvals | CCC, CSA, EAC, IEC, RoHS, UL | |
| Length | 58mm | |
| Better World Product | Yes | |
| Pole and Throw Configuration | 3 | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Coil Voltage 230V ac | ||
Product Type Reversing Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V ac | ||
Contact Current 6A | ||
Power Rating 4kW | ||
Series TeSyS K | ||
Mount Type Plate, Rail Mount | ||
Function Motor Control, Resistive Load, Reversing | ||
Normal State Configuration 3 NO | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NC | ||
Terminal Type Screw Clamp | ||
Minimum Operating Temperature -25°C | ||
Control Circuit Voltage Uc 230V ac | ||
Contactor Application Motor Control | ||
Operational Current Ie 6A | ||
Maximum Operating Temperature 50°C | ||
Depth 57mm | ||
Width 90mm | ||
Standards/Approvals CCC, CSA, EAC, IEC, RoHS, UL | ||
Length 58mm | ||
Better World Product Yes | ||
Pole and Throw Configuration 3 | ||
Schneider Electric LC2K Series Reversing Contactor, 6A Contact Current, 230V Coil Voltage - LC2K0601P7
This reversing contactor is a Compact motor control device designed to reverse three-phase motors and manage control circuits in industrial settings. It operates from a 230V AC control supply and is preassembled with a reversing power busbar for straightforward installation, providing switching capability up to 690V in power and signalling circuits while supporting AC-3 and AC-4 utilisation categories.
Features & Benefits
• 6A operational current delivers effective small motor switching
• 4 kW power rating enables control of modest industrial motors
• 1 NC auxiliary contact provides Basic interlock and signalling
• Screw clamp terminals allow secure 0.34 to 4mm² conductor connections
• Mechanical interlock prevents simultaneous forward and reverse closing
• 110A rated breaking capacity ensures short-duration fault handling
• 4 kW power rating enables control of modest industrial motors
• 1 NC auxiliary contact provides Basic interlock and signalling
• Screw clamp terminals allow secure 0.34 to 4mm² conductor connections
• Mechanical interlock prevents simultaneous forward and reverse closing
• 110A rated breaking capacity ensures short-duration fault handling
Applications
• Suitable for reversing conveyor and belt-drive motors
• Ideal for forward/reverse control of pump motors
• Used for small machine-tool motor direction control
• Can be used for automated material-handling systems
• Ideal for forward/reverse control of pump motors
• Used for small machine-tool motor direction control
• Can be used for automated material-handling systems
What are the environmental limits for operation?
It operates reliably between -25 °C and 50 °C and is suitable for altitudes up to 2000 m without derating.
How does it perform under repeated operation cycles?
Mechanical endurance is rated to 5 Mcycles with electrical durability of 1.3 Mcycles at 6A AC-3 for Ue ≤ 440 V.
Which mounting options are available for panel fitment?
It supports both rail and plate mounting for flexible enclosure or DIN-rail installations.
What electrical protection and fault capacities exist?
Associated fuse recommendations include 25A gG for power circuits at ≤ 440V and short-time withstand currents up to 90A for 1 s at 50 °C.
How are Coil power requirements specified?
Inrush consumption is 30 VA and hold-in consumption is 4.5 VA at 20 °C for the 230V AC control coil.
Certificate No.
UL, CSA.
Standards
VDE 0660, BS 5424, IEC 60947, NF C 63-110.