Block 2 Output 500 VA Chassis Mount Transformer, 2 x 115 V ac, IEC 61558-2-2, VDE 0570 Part 2-4, CSA 22.2 No.66, VDE
- RS庫存編號:
- 361-8115
- 製造零件編號:
- STEU500/23
- 製造商:
- Block
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
查看批量定價選項小計(1 件)*
TWD6,619.00
(不含稅)
TWD6,949.95
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 56 件準備從其他地點送貨
- 加上 1 件從 2026年9月17日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 24 | TWD6,619.00 |
| 25 + | TWD6,453.00 |
* 參考價格
- RS庫存編號:
- 361-8115
- 製造零件編號:
- STEU500/23
- 製造商:
- Block
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Block | |
| Product Type | Chassis Mount Transformer | |
| Primary Voltage | 400 V ac, 230 V | |
| Secondary Voltage | 2 x 115 V ac | |
| Number of Outputs | 2 | |
| Power | 500VA | |
| Maximum Operating Temperature | 40°C | |
| Length | 120mm | |
| Series | STEU 500/23 | |
| Weight | 7.7kg | |
| Depth | 124mm | |
| Width | 120mm | |
| Minimum Operating Frequency | 50Hz | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | IEC 61558-2-2, VDE 0570 Part 2-4, CSA 22.2 No.66, VDE 0570 Teil 2-2, UL 5085-1/-2, IEC 61558-2-4, EN 61558-2-2, EN 61558-2-4, DIN EN 61558-2-2, DIN EN 61558-2-4 | |
| 選取全部 | ||
|---|---|---|
品牌 Block | ||
Product Type Chassis Mount Transformer | ||
Primary Voltage 400 V ac, 230 V | ||
Secondary Voltage 2 x 115 V ac | ||
Number of Outputs 2 | ||
Power 500VA | ||
Maximum Operating Temperature 40°C | ||
Length 120mm | ||
Series STEU 500/23 | ||
Weight 7.7kg | ||
Depth 124mm | ||
Width 120mm | ||
Minimum Operating Frequency 50Hz | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals IEC 61558-2-2, VDE 0570 Part 2-4, CSA 22.2 No.66, VDE 0570 Teil 2-2, UL 5085-1/-2, IEC 61558-2-4, EN 61558-2-2, EN 61558-2-4, DIN EN 61558-2-2, DIN EN 61558-2-4 | ||
- COO (Country of Origin):
- DE
Safety Isolating Transformer
Safety isolating and isolating control transformers
Twin secondary winding for series or parallel connection
63,100,160 and 250VA transformers can be mounted on standard 35mm DIN rail
All units have 4 hole panel mount fixings
Easy installation 4mm² cage clamp terminals
Insulation catagory Class B
Primary connections 0V, -15V, +15V, 230V, 400V. The + 15 and -15V allows you to offset the primary Voltage by 15V
Low inrush current
High efficiency, low regulation
Approvals
UL Recognised Component for Canada & US
Standards
EN 61558, VDE0570
相關連結
- Block 2 x 18 V ac 2 Output Pin PCB Transformer DIN EN 61558-2-6 VDE
- Block 2 x 18 V ac 2 Output PCB PCB Transformer IEC 61558-2-6 CSA 22.2 No.66 UL
- Block 2 x 9 V ac 2 Output Pin PCB Transformer cURus VDE VDE 0570 Part
- Block 2 x 18 V ac 2 Output Pin PCB Transformer IEC 61558-2-6 UL 5085-1/-2 EN
- Block 15 V ac 2 Output Pin PCB Transformer VDE 0570 part 2-1 IEC 61558-2-1, ENEC
- Block 2 x 12 V ac 2 Output Pin PCB Transformer DIN EN 61558-2-6 cURus, IEC
- Block 6 V ac 2 Output Solder PCB Transformer VDE 0570/EN 61558 EN 61558-2-6, UL 506 1 VA
- Block 9 V ac 1 Output Pin PCB Transformer VDE 0570 Part 2-6 IEC 61558-2-6, ENEC