Block 2 Output 200 VA Chassis Mount Transformer, 2 x 115 V ac, EN 61558-2-4, VDE 0570 Part 2-4, DIN EN 61558-2-4, IEC
- RS庫存編號:
- 278-7096
- Distrelec 貨號:
- 156-14-532
- 製造零件編號:
- TIM 200
- 製造商:
- Block
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 件)*
TWD2,851.00
(不含稅)
TWD2,993.55
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 3 件從 2026年3月19日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 9 | TWD2,851.00 |
| 10 - 24 | TWD2,780.00 |
| 25 - 49 | TWD2,710.00 |
| 50 - 99 | TWD2,656.00 |
| 100 + | TWD2,603.00 |
* 參考價格
- RS庫存編號:
- 278-7096
- Distrelec 貨號:
- 156-14-532
- 製造零件編號:
- TIM 200
- 製造商:
- Block
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Block | |
| Primary Voltage | 230 V ac | |
| Product Type | Chassis Mount Transformer | |
| Secondary Voltage | 2 x 115 V ac | |
| Number of Outputs | 2 | |
| Power | 200VA | |
| Fixing Hole Diameter | 4.3mm | |
| Maximum Operating Temperature | 40°C | |
| Minimum Operating Frequency | 50Hz | |
| Series | TIM 200 | |
| Width | 117 mm | |
| Depth | 223mm | |
| Weight | 3.60kg | |
| Length | 223mm | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | EN 61558-2-4, VDE 0570 Part 2-4, DIN EN 61558-2-4, IEC 61558-2-4 | |
| 選取全部 | ||
|---|---|---|
品牌 Block | ||
Primary Voltage 230 V ac | ||
Product Type Chassis Mount Transformer | ||
Secondary Voltage 2 x 115 V ac | ||
Number of Outputs 2 | ||
Power 200VA | ||
Fixing Hole Diameter 4.3mm | ||
Maximum Operating Temperature 40°C | ||
Minimum Operating Frequency 50Hz | ||
Series TIM 200 | ||
Width 117 mm | ||
Depth 223mm | ||
Weight 3.60kg | ||
Length 223mm | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals EN 61558-2-4, VDE 0570 Part 2-4, DIN EN 61558-2-4, IEC 61558-2-4 | ||
- COO (Country of Origin):
- DE
Single Phase 230Vac Input, 12Vac or 24Vac and 115Vac or 230Vac Output, Short Circuit Proof, Safety Isolating Transformers
Brought to you by Block, this range of Safety Isolating Transformers are short-circuit proof and feature thermal overload protection. The single phase transformers are provided with mounting holes for easy installation, and have two independent secondary windings, which may be connected in series or parallel. These highly efficient safety isolating transformers have integrated primary fuse protection.
Block Safety Isolating Transformers benefit from the following features:
• Encapsulated in plastic housing upto 300VA
• Housed in metal enclosures from 500VA
• Screw terminals on input and output
• Strain relief for connecting leads
• Dual output for series or parallel connection
• High efficiency 88% typical
• 100% electrical and 5kV flash tested
• Max ambient temp: +40°C
• Insulation category: Class B (Typical)
• Construction: Class 2
• Protection index: IP20
Approvals
EN61-558, VDE 0570, UL506.
Standards
EN61558, VDE 0570, UL506.
相關連結
- Block 2 Output 100 VA Chassis Mount Transformer DIN EN 61558-2-4 VDE 0570 Part 2-4, IEC
- Block 2 Output 300 VA Chassis Mount Transformer VDE 0570 Part 2-4 DIN EN 61558-2-4
- Block 2 Output 60 VA Chassis Mount Transformer VDE VDE 0570 Part 2-4
- Block 63 VA Chassis Mount Transformer DIN EN 61558-2-2 VDE 0570 part 2-2 2-4, UL
- Block 2 x 15 V 2 Output Pin PCB Transformer VDE 0570 part 2-1 IEC 61558-2-1, ENEC
- Block 9 V 1 Output Pin PCB Transformer VDE 0570 Part 2-6 IEC 61558-2-6, ENEC 10
- Block 18 V 1 Output Pin PCB Transformer IEC 61558-2-1 VDE 0570 part 2-1, VDE 0570
- Block 100 VA Chassis Mount Transformer VDE 0570 Teil 2-6 EN 61558-2-2
