Eaton 0.8 kVA Chassis Mount Transformer, 230 V, VDE 0100 Part 410 UL 506 CSA-C22.2 No. 66.1-06, CE CSA-C22.2 No. 66
- RS庫存編號:
- 252-978
- 製造零件編號:
- 204990 STN0,8(400/230)
- 製造商:
- Eaton
小計(1 件)*
TWD7,433.00
(不含稅)
TWD7,804.65
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年4月06日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD7,433.00 |
* 參考價格
- RS庫存編號:
- 252-978
- 製造零件編號:
- 204990 STN0,8(400/230)
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Primary Voltage | 400 ± 5 % V | |
| Product Type | Chassis Mount Transformer | |
| Secondary Voltage | 230 V | |
| Power | 0.8kVA | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 40°C | |
| Weight | 7.78kg | |
| Length | 124mm | |
| Width | 151 mm | |
| Minimum Operating Frequency | 50Hz | |
| Depth | 150mm | |
| Series | STN | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | VDE 0100 Part 410 UL 506 CSA-C22.2 No. 66.1-06, CE CSA-C22.2 No. 66 CSA-C22.2 No. 66.2-06 UL Category Control No.:XPTQ2, XPTQ8 UL Report Applies to both US and Canada IEC/EN 61558-2-2 VDE 0570 Part 2-2 IEC/EN 60204-1, ÖVE-EN 13 UL File No.:E167225 UL5085-1 Certified by UL for use in Canada UL 5085-2 UL VDE 0113 | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Primary Voltage 400 ± 5 % V | ||
Product Type Chassis Mount Transformer | ||
Secondary Voltage 230 V | ||
Power 0.8kVA | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 40°C | ||
Weight 7.78kg | ||
Length 124mm | ||
Width 151 mm | ||
Minimum Operating Frequency 50Hz | ||
Depth 150mm | ||
Series STN | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals VDE 0100 Part 410 UL 506 CSA-C22.2 No. 66.1-06, CE CSA-C22.2 No. 66 CSA-C22.2 No. 66.2-06 UL Category Control No.:XPTQ2, XPTQ8 UL Report Applies to both US and Canada IEC/EN 61558-2-2 VDE 0570 Part 2-2 IEC/EN 60204-1, ÖVE-EN 13 UL File No.:E167225 UL5085-1 Certified by UL for use in Canada UL 5085-2 UL VDE 0113 | ||
豁免
- COO (Country of Origin):
- HU
The Eaton Moeller series STN Control transformer is engineered for exceptional reliability, providing an optimal solution for your power supply needs. With an impressive 0.8 kVA rating and dual voltage capability of 400 V input and 230 V output, this transformer is perfect for various industrial applications. Designed to withstand demanding operational conditions, the product features fully vacuum-impregnated windings that ensure durability and longevity. With compliance to stringent certifications, including CE and UL recognitions, this transformer guarantees safety and performance, making it an indispensable addition to your power system setup. Furthermore, its compact design allows for easy integration into existing installations, while its high efficiency helps reduce operational costs, aligning with sustainability goals.
Robust construction with separate windings for enhanced safety
High efficiency reduces energy waste and operational costs
Temperature ratings accommodate a wide ambient range
Connection options available for flexible installation
High standard certifications ensure compliance with international safety norms
Designed for single-phase applications, perfect for branch circuits
Fully vacuum-impregnated to resist environmental challenges
Minimal no-load and short-circuit losses for improved performance
Compact dimensions facilitate installation in space-constrained environments
相關連結
- Eaton 0.16 kVA Chassis Mount Transformer UL Category Control No.: XPTQ2 CSA-C22.2 No. 66.1-06
- Eaton 0.16 kVA Chassis Mount Transformer UL 5085-2 VDE 0113 VDE 0570
- Eaton 0.5 kVA Chassis Mount Transformer CSA-C22.2 No. 66.1-06 VDE 0113, VDE
- SolaHD 45 kVA Chassis Mount Transformer UL 1561 UL Listed/NEMA Type 3R, UL 506
- Eaton 0.25 kVA Chassis Mount Transformer CE CSA-C22.2 No. 66 UL UL5085-1 UL 5085-2 CSA-C22.2
- Eaton 0.315 kVA Chassis Mount Transformer XPTQ8, VDE 0100 Part 410 by UL for use in Canada CSA-C22.2 No. 66.2-06
- Eaton 1 kVA Chassis Mount Transformer ÖVE-EN 13 CSA-C22.2 No. 66.2-06 VDE 0570 Part 2-2 UL 506 UL5085-1 UL
- Eaton 1 Output 0.06 kVA Chassis Mount Transformer IEC/EN 61558-2-2 VDE 0570 part 2-2, CSA-C22.2 No.