Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland, M20 x 1.5 Thread, 7 mm min., 13 mm max., IP68, IP69
- RS庫存編號:
- 400-124
- 製造零件編號:
- 53112020LF
- 製造商:
- Lapp
小計(1 袋,共 5 件)*
TWD4,895.00
(不含稅)
TWD5,139.75
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 3 件從 2026年5月12日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
袋 | 每袋 | 每單位* |
|---|---|---|
| 1 + | TWD4,895.00 | TWD979.00 |
* 參考價格
- RS庫存編號:
- 400-124
- 製造零件編號:
- 53112020LF
- 製造商:
- Lapp
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Lapp | |
| Product Type | Cable Gland | |
| Thread Size | M20 x 1.5 | |
| Maximum Cable Diameter | 13mm | |
| Minimum Cable Diameter | 7mm | |
| Material | Nickel Plated Brass | |
| Colour | Nickel | |
| Series | SKINTOP MS-M | |
| IP Rating | IP68, IP69 | |
| Hazardous Area Certification | NO | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 100°C | |
| Standards/Approvals | DIN EN 60423, DIN IEC 62444, DNV, UL, VDE | |
| 選取全部 | ||
|---|---|---|
品牌 Lapp | ||
Product Type Cable Gland | ||
Thread Size M20 x 1.5 | ||
Maximum Cable Diameter 13mm | ||
Minimum Cable Diameter 7mm | ||
Material Nickel Plated Brass | ||
Colour Nickel | ||
Series SKINTOP MS-M | ||
IP Rating IP68, IP69 | ||
Hazardous Area Certification NO | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 100°C | ||
Standards/Approvals DIN EN 60423, DIN IEC 62444, DNV, UL, VDE | ||
- COO (Country of Origin):
- DE
LAPP SKINTOP MS-M Series Cable Gland, M20 x 1.5 Thread size, Nickel - 53112020LF
This cable gland provides a secure conduit entry solution for industrial and marine installations, designed to maintain enclosure integrity against dust and water ingress. It is constructed in a corrosion-resistant nickel finish and threaded for straightforward panel installation, offering reliable performance across a wide temperature range for use in automation, electrical and mechanical systems.
Features and Benefits:
• IP66/IP68/IP69 protection maintains enclosure sealing under harsh conditions
• Nickel-plated brass body resists corrosion in saline and humid atmospheres
• Withstands continuous operation between -40°C and 100°C for thermal stability
• Accepts cable diameters from 7mm to 13mm for flexible cable selection
• M20x1.5 thread ensures compatibility with standard metric gland entries
• Conforms to DIN EN 60423 and DIN IEC 62444 to support regulatory fitments
• Nickel-plated brass body resists corrosion in saline and humid atmospheres
• Withstands continuous operation between -40°C and 100°C for thermal stability
• Accepts cable diameters from 7mm to 13mm for flexible cable selection
• M20x1.5 thread ensures compatibility with standard metric gland entries
• Conforms to DIN EN 60423 and DIN IEC 62444 to support regulatory fitments
Applications
• Suitable for cable entry on control cabinets in factory automation
• Ideal for junction boxes on marine vessels requiring DNV compliance
• Used for power and signal cables in process plant electrical installations
• Can be used for sensor and actuator cable terminations in robotics
• Suitable for outdoor instrumentation exposed to washdown conditions
• Ideal for junction boxes on marine vessels requiring DNV compliance
• Used for power and signal cables in process plant electrical installations
• Can be used for sensor and actuator cable terminations in robotics
• Suitable for outdoor instrumentation exposed to washdown conditions
What mechanical material offers durability against mechanical wear?
The gland is manufactured from nickel-plated brass, which combines metallic strength with surface corrosion resistance for prolonged mechanical service life.
How does it perform during high-pressure cleaning or steam-jet washdowns?
Rated to IP69, it withstands high-temperature, high-pressure washdowns, maintaining ingress protection under direct, powerful water jets.
What thread specification is required for panel cut-outs?
Panels must accept an M20x1.5 threaded entry to secure the gland correctly and preserve sealing performance.
Which industry approvals indicate electrical safety recognition?
The component carries approvals from UL and VDE for recognised electrical conformity in applicable installations.
How does the design accommodate different cable sizes without separate accessories?
The sealing geometry is compatible with cable diameters from 7mm to 13 mm, allowing a single gland to service a range of cable cross-sections.
相關連結
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 7 mm min. IP69, IP68
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 19 mm min. IP68, IP69
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 4.5 mm min. IP68, IP69
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 3.5 mm min. IP68, IP69
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 11 mm min. IP69, IP68
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 35 mm min. IP68, IP69
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 27 mm min. IP69, IP68
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 9 mm min. IP69, IP68