Schneider Electric Auxiliary Contact, 1 Contact, 1 NO/1 NC, ComPacT NSXm, Clip-on, 5 A, 110 V dc, 690V ac, LV426950

小計(1 件)*

TWD1,018.00

(不含稅)

TWD1,068.90

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 12 件準備從其他地點送貨
  • 加上 30 件從 2026年10月16日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD1,018.00

* 參考價格

RS庫存編號:
178-7894
製造零件編號:
LV426950
製造商:
Schneider Electric
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Schneider Electric

Product Type

Auxiliary Contact

Number of Contacts

1

Normal State Configuration

1 NO/1 NC

Series

ComPacT NSXm

Contact Current

5A

Mount Type

Clip-on

Terminal Type

Cage Clamp

Pole and Throw Configuration

1P

Contact Voltage

110V dc, 690V dc

Minimum Load

2mA

Operational Current Ie

5A

Standards/Approvals

No

Schneider Electric LV42 Series Auxiliary Contact, 5A Operational Current, 690V Contact Voltage - LV426950


This auxiliary contact provides electrical status signalling for circuit breakers and contactors within industrial electrical systems. It is a clip-on, spring-terminal device offering one normally open and one normally closed contact to monitor open/close and relay trip conditions in low- and medium-voltage assemblies.

Features & Benefits


• 5A operational current for direct control of signal circuits
• 690V rated contact voltage for high-voltage signalling applications
• Minimum load 2mA enables reliable detection of very low currents
• Spring Terminal with 8mm stripping length for quick wiring
• Clip-on mounting for Rapid attachment to compatible breakers
• 1P configuration supplying both NO and NC status outputs

Applications


• Suitable for breaker status monitoring in distribution panels
• used with PowerPact and ComPact range breakers for feedback signals
• Suitable for contactors requiring auxiliary changeover indication
• Used for local open/closed indication and relay trip signalling

What Terminal style is provided for wiring?


It uses spring-type terminals designed for a front connection with an 8mm wire stripping length to ensure secure, tool-minimised terminations.

How does it indicate fault or trip conditions?


The contacts supply ON/OFF status outputs

the NO/NC pair can be wired to local indicators or a trip relay to signal overload or short-circuit events.

What breaking capacities can it handle across AC and DC?


It carries 5A for many AC control categories up to 690V and varying lower ratings for AC-15 and DC control categories, with reduced currents at higher voltages and for DC categories.

Which mounting method allows fast integration into existing switchgear?


The clip-on mounting enables swift fitting onto compatible devices without additional hardware, aiding modular assembly and maintenance.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。