RS PRO Type K Exposed Junction Thermocouple 3 m Length, → 250 °C Max

可享批量折扣

小計(1 件)*

TWD486.00

(不含稅)

TWD510.30

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 64 件準備從其他地點送貨
  • 加上 140 件從 2026年4月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。

單位
每單位
1 - 4TWD486.00
5 - 24TWD466.00
25 +TWD382.00

* 參考價格

RS庫存編號:
131-4754
Distrelec 貨號:
304-14-009
製造商:
RS PRO
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

RS PRO

Thermocouple Type

K

Product Type

Exposed Junction Thermocouple

Probe Length

3m

Maximum Temperature Sensed

250°C

Probe Material

PFA

Cable Length

3m

Standards/Approvals

IEC, RoHS Compliant

COO (Country of Origin):
GB

RS Pro IEC Type K Exposed Junction Fast Response Thermocouple with Moulded Miniature Plug


From RS Pro a range of type K thermocouple temperature sensors conforming to IEC-584-3 standards with a Class 1 tolerance. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The twin-twisted leads have a durable Teflon PFA insulation and are terminated one end with a moulded miniature flat pin plug which is colour coded green in accordance with IEC. The moulded plug has a a robust construction, provides a waterproof termination and enables a quick and easy connection.

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


A welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Features and Benefits


• Welded, exposed junction for fast response times

• IEC-584-3 Class 1 tolerance for optimum accuracy

• Durable Teflon PFA lead insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility

• Miniature moulded plug with robust design for quick connection and waterproof termination

• Temperature range of -75 to +250°C

Applications


Exposed junction thermocouples are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Applications include test and development, test and measurement, temperature mapping and OEM applications.

Note

Small Pack Size:131-4754