RS Pro 70 MHz High Voltage Differential Probe RSDPB5150
Bandwidth DC-70 MHz Rise time ≤5 ns DC accuracy ±2% Attenuation ratio 50 X/500 X Maximum differential test voltage (DC + Peak AC) 50 X: 150 V, 500 X: 1500 V Maximum input common mode voltage (voltage-to-earth Vrms) 600 V CATIII, 1000 V CATII Input impedance single-ended to ground 5 MΩ, two inputs 10 MΩ Input capacitance single-ended to ground <4 pF, two inputs <2 pF CMRR: DC >80 dB; 100 kHz >60 dB; 1 MHz >50 dB Propagation delay 18 ns ± 1 ns Bandwidth limit ≥ -3 dB @ 5 MHz Differential overvoltage detection level 50 X: ≥150 V, 500 X: ≥1500 V Overload indicator(red light) Overload alarm Automatic save Offset setting function Terminate load 1 MΩ Power supply USB 5 V/1 A adapter Probe body dimensions 195 x 65 x 28 mm Probe body weight approximately 188 g
RS PRO Differential Probe - RSDPB5150
The RS PRO RSDPB5150 is a high voltage differential probe is a high-quality device designed to measure differential signals. They work with a conventional oscilloscope to display waveforms by measuring the voltage difference between two points to produce a much cleaner signal.
Why would you need a Differential Probe?
Design engineers are frequently turning to differential probes due to the advantages over single-ended probes when it comes to accuracy and ease of use. Differential probes can retain high common-mode rejection by removing the common noise. The true differential noise is extracted so you can see a more accurate signal on the oscilloscope screen.
Also known as;
Oscilloscope Probe
Key Advantages
High voltage differential probe High common-mode rejection Probe loading is significantly reduced Higher bandwidth No ground-bounce Accurate measurement Ease of use
Specifications
Bandwidth DC-70 MHz Rise time ≤5 ns DC accuracy ±2% Attenuation ratio 50 X/500 X Maximum differential test voltage (DC + Peak AC) 50 X: 150 V, 500 X: 1500 V Maximum input common-mode voltage (voltage-to-earth Vrms) 600 V CATIII, 1000 V CATII Input impedance single-ended to ground 5 MΩ, two inputs 10 MΩ Input capacitance single-ended to ground <4 pF, two inputs <2 pF CMRR: DC >80 dB; 100 kHz >60 dB; 1 MHz >50 dB Propagation delay 18 ns ± 1 ns Bandwidth limit ≥ -3 dB @ 5 MHz Differential overvoltage detection level 50 X: ≥150 V, 500 X: ≥1500 V Overload indicator (red light) Overload alarm Automatic save Offset setting function Terminate load 1 MΩ Power supply USB 5 V/1 A adapter Probe body dimensions 195 x 65 x 28 mm Probe bodyweight approximately 188 g
Applications
Floating voltage measurement Frequency converters Switching power supplies designs Motor driven design Electronic ballast design CRT displayer design Inverter, UPS power supplies Frequency conversion electrical appliances Power conversion and related design Electrical engineering experiment Low voltage appliances experiment Power electronics and electric drive experiments