Siemens, Sentron MCCB Molded Case Circuit Breaker 100 A, Breaking Capacity 25 kA, Fixed Mount
- RS庫存編號:
- 874-4152
- 製造零件編號:
- 3VA1110-3EE36-0AA0
- 製造商:
- Siemens
不可供應
RS 不再對此產品進貨。
- RS庫存編號:
- 874-4152
- 製造零件編號:
- 3VA1110-3EE36-0AA0
- 製造商:
- Siemens
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Siemens | |
| Range | Sentron | |
| Series | 3VA | |
| Number of Poles | 3 | |
| Current Rating | 100A | |
| Breaking Capacity at Maximum Voltage Rating | 25 kA | |
| Rated AC Voltage | 690V | |
| Rated DC Voltage | 500V | |
| Length | 76.2mm | |
| Width | 130mm | |
| Depth | 88mm | |
| Circuit Breaker Type | MCCB | |
| Break Time | Instantaneous | |
| Tripping Mechanism | Thermal-Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Mounting Hole Diameter | 4.2mm | |
| 選取全部 | ||
|---|---|---|
品牌 Siemens | ||
Range Sentron | ||
Series 3VA | ||
Number of Poles 3 | ||
Current Rating 100A | ||
Breaking Capacity at Maximum Voltage Rating 25 kA | ||
Rated AC Voltage 690V | ||
Rated DC Voltage 500V | ||
Length 76.2mm | ||
Width 130mm | ||
Depth 88mm | ||
Circuit Breaker Type MCCB | ||
Break Time Instantaneous | ||
Tripping Mechanism Thermal-Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Mounting Hole Diameter 4.2mm | ||
- COO (Country of Origin):
- CZ
Siemens 3VA1 MCCBs
The new 3VA1 molded case circuit breakers reliably perform all the tasks associated with line protection.
The devices of the 3VA1 series fulfill all standard tasks in line protection, thanks to their particularly compact design, 3VA1 MCCBs are the perfect choice for applications in distribution boards and machine engineering.
They are easily mounted as fixed or plug-in versions.
The basic trigger for overload or short-circuit protection is a thermal-magnetic, electronic trip unit (TMTU) and is suitable for use in three-phase, AC, and DC networks.
The devices of the 3VA1 series fulfill all standard tasks in line protection, thanks to their particularly compact design, 3VA1 MCCBs are the perfect choice for applications in distribution boards and machine engineering.
They are easily mounted as fixed or plug-in versions.
The basic trigger for overload or short-circuit protection is a thermal-magnetic, electronic trip unit (TMTU) and is suitable for use in three-phase, AC, and DC networks.
Compact design
Thermal-magnetic trip units
AC/DC applications
No derating up to +50 °C
Thermal-magnetic trip units
AC/DC applications
No derating up to +50 °C
Siemens 3VA MCCBs and accessories